Toa RS-180 Installation User Manual
Installation manual
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.
4. MOUNTING
YC-822/823
Wall surface
Note
Machine screw M4 x 25
(accessory)
In the case of the YC-823,
install it facing the ø6 mm
weep hole side down.
YC-823 bottom
ø6 mm weep hole
RS-150/160/170/180
Note
This figure is
the YC-822.
Note
This figure is
RS-160/170.
RS-150/160/170/180
Machine screw M4 x 25
(accessory)
2-gang electrical box
YC-302 (optional)
Wall surface
Note
This figure is
RS-160/170.
[Flush mounting using an electrical box]
[Wall surface mounting using the Wall-mount box]
Note
When using the PA paging function, keep the station as far away from the PA paging
speaker as possible to avoid acoustic feedback.
The RS-150, RS-160, RS-170, and RS-180 come with 2
types of screws: M4 x 25 and UNC No. 6-32 x 18.
For the electrical box provided with unified threads, use the
UNC No. 6-32 x 18 screw.
Accessory screws
46
120
52.5
*2
*2
43.5 (RS-150)
*1
2 (RS-150)
3
*1
37
18.2
83.5
120
[Dimensional diagram]
10
φ28 hole
8-5×7 oval hole (for wall mounting)
4-M4 (for substation mounting)
46
84
124
φ6 weep hole
83.5
73
61
10
62
83
66.7
124
[YC-823 dimensional diagram]
Unit: mm
φ28 (Knockout hole)
60
30
46
84
124
φ28 hole
83.5
73
83
66.7
8-5×7 oval hole (for wall mounting)
4-M4 (for substation mounting)
124
[YC-822 dimensional diagram]
Unit: mm
Unit: mm
Traceability Information for Europe (EMC directive 2004/108/EC)
Manufacturer:
TOA Corporation
7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo, Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg, Germany
133-06-228-9F
URL: http://www.toa.jp/
Mount the substation to an electrical box mounted to the wall. Attach the Substation to the YC-822 (Indoor wall-mount
box) or YC-823 (Outdoor wall-mount box)
installed on a
wall.
RS-150, RS-160, RS-170, RS-180
SUbSTATION
INSTALLATION MANUAL
1. GENERAL DESCRIPTION
TOA's RS-150, RS-160, RS-170, and RS-180 are Substations designed to be used with TOA's VS-900 Voice Security
System and N-8000 Series Packet Intercom System.
䇯
Thank you for purchasing TOA's Substation.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
Note: For operation of the units, refer to the VS-900 operating instructions or the N-8000 series operating
instructions.
3. CONNECTIONS
[Connection to the VS-900RS, N-8000RS, N-8010RS (for 25 V line)]
Model No.
RS-150
RS-160
RS-170
RS-180
Rated Input
1 W
Rated Impedance
625 Ω (1 W, 25 V)
Internal Speaker
4 cm dynamic type
Transmission Range
0.5 km/ø0.5 mm (AWG24)
0.8 km/ø0.65 mm (AWG22)
1.3 km/ø0.9 mm (AWG19)
Control Output
(RS-180 only)
Open collector, Withstand voltage: 30 V DC,
Control current: 30 mA
(The open collector output is kept turned on till the conversation
is finished after the call button was pressed.)
Operating Temperature
–10 to +50°C
(Temperature range not to freeze the speaker and switch)
Finish
(Panel)
Stainless steel, hairline
(Call button)
Resin
Metal
(Printed circuit board)
(RS-170, RS-180 only) Weather-resistant coating
Dimensions
(w)
120 mm
(h)
120 mm
(d)
48.5 mm
57.5 mm
58.5 mm
Weight
410 g
540 g
570 g
Accessories
Machine screw M4 x 25 ... 4, UNC No. 6-32 x 18 ... 4
Applicable Box (For flush-mount)
2-gang electrical box: YC-302 (option)
(For surface-mount)
Wall-mount box: YC-822 (option)
Wall-mount box: YC-822/YC-823 (option)
Open collector output
(RS-180 only)
(VS-900RS,
N-8000RS, or
N-8010RS)
A
B
C
Orange
Brown
Black
Speaker
Call button
Status indicator
(RS-180 only)
Blue (HOT)
White (COM)
RS-150/160/170/180
External
power supply
Relay
Diode
24 V DC
+
-
Blue (HOT)
White (COM)
RS-180
GND
Open collector output: 24 V DC (max.), 30 mA
[Connection to the external relay (RS-180 only)]
Note
Cut out the control cables if they are
not used to avoid short-circuiting.
2. SPECIFICATIONS
Note: The design and specifications are subject to change without notice for improvement.