854 sprayer control – TeeJet 854 Sprayer Control User Manual
Page 47
www.teejet.com
42
854 Sprayer Control
Tank Volume Feature
The console will count down the volume remaining
in the tank and alert the operator when the Lo Tank
Level has been reached. The Lo Tank Level can be
programmed by the operator during System Setup
Mode.
Viewing Remaining Tank Volume
• While spraying in normal operating mode, with
the Master Boom Switch in the “On” position,
press and hold the TANK key.
• The lower right display of the console will show
the volume remaining in the tank.
• When the volume reaches the pre-programmed
level, the audible alarm will activate. The display
will switch to the Tank Volume Display.
• To acknowledge the alarm, press the TANK
key or the PROGRAM key. This will return the
console to normal operating view.
NOTE: An audible alarm is activated when this
feature is enabled. It will provide a long
beep, indicating Low Priority.
Figure 7-5: Tank Volume
348
32
6.4
Resetting Tank Volume
To reset the tank volume:
• Press the TANK key.
• Use the PLUS or MINUS keys to enter a
partial tank volume
• Press the AUTO/MAN key to reset the tank
volume counter to the maximum value of the
tank volume.
• Press the TANK key or PROGRAM key
to return to normal operating view.
Figure 7-6: Resetting Tank Volume
1000
Application.Alarm
If the 854 senses a continuous discrepancy of 10%
or more between the Target Application Rate and the
Actual Application Rate, the application rate window
will flash.
This will alert the operator to a problem with the
sprayer plumbing, operation, or programming.
NOTE: An audible alarm is activated when this
feature is enabled. It will provide three short
beeps, indicating High Priority.
Figure 7-7: Application Alarm
MPH
17.4
7.0
49
530