21

854 Sprayer Control

Figure 4-19: Section Valve Type

2

SEC

tYPE

Pressure.Regulating.Mode

The Pressure Regulating Mode instructs the 854

where the regulating valve is plumbed into the

system. Once configured correctly, this value should

not change unless the regulating valve is physically

moved to a new point in the plumbing.

• The default value is “BYP” which indicates that

the pressure regulating valve is plumbed in a

bypass line.

• If the setting is correct, press the PROGRAM

key to accept the value and advance to the

next step.

When programmed in the Bypass Mode, with the

controller in Manual Mode “Man”, the pressure

regulating valve should:

• Close when the PLUS key is pressed.
• Open when the MINUS key is pressed.

Figure 4-20: Pressure Regulating Mode

bYP

re6

If the pressure regulating valve is plumbed in a

supply line to the booms, it is considered in the

“throttling” position.

• Use the PLUS or MINUS keys to adjust

the value to “thr” (throttling mode). The polarity

that the console uses to control the regulating

valve will be reversed.

• Press the PROGRAM key to accept the

value and advance to the next step.

When programmed in the Throttling Mode, with

the controller in Manual Mode “Man”, the pressure

regulating valve should:

• Open when the PLUS key is pressed.
• Close when the MINUS key is pressed

Figure 4-21: Pressure Regulating Mode

THr

re6