854 Sprayer Control

Figure 4-28: Automatic Calibration

CAL

CAL

0

As the known volume is pumped, the console will

count the pulses.

• Once the volume has been pumped, turn the

pump (or flow) off to stop counting pulses.

Figure 4-29: Automatic Calibration (continued)

CAL

56

3856

• Press the PROGRAM key. The console will

ask what volume was pumped.

• Use the PLUS and MINUS keys to adjust

the value to match the volume pumped (in

gallons/liters).

Figure 4-30: Automatic Calibration (continued)

6AL 1000

• Press the PROGRAM key to return to

programming mode.

• The new flow meter calibration will be

displayed.

• Press the PROGRAM key to accept the

value and advance to the next step.

• Follow the same procedures to repeat the

calibration process.

Figure 4-31: Automatic Calibration (continued)

FIL

67.00

PLS

FLO