Mem load re, 854 sprayer control – TeeJet 854 Sprayer Control User Manual
Page 37
www.teejet.com
32
854 Sprayer Control
Memory.Reload.Function
The memory reload function is used to restore all
programming values that were previously set. A
sprayer manufacturer can pre-program the console
for specific parameters on a sprayer and save the
values internally. This step will allow for the return to
those pre-programmed values if required.
WARNING! It is recommended that this setting be
set to “NO” unless otherwise instructed by
an authorized TeeJet representative.
Notes: For protection, the 854 console does not
automatically power down while in Program
Mode. Exit properly as described below
to enable the console’s auto power down
feature.
Cutting the power to the controller while in
Program Mode will not save any changes in
the computer’s memory.
• Use the PLUS or MINUS keys to select
either “YES” or “NO”.
• The default of “NO” indicates that programming
values are saved as entered.
• Selecting “YES” will change the program
values to those programmed and saved by the
manufacturer.
• Press the PROGRAM key to advance to
the next step. The screen should return to the
beginning of Program Mode.
• Press and hold the PROGRAM key for
three seconds to exit Program Mode and save
the programming information to the console’s
memory.
Figure 4-49: Memory Reload Function
MEM
LOAD
rE