beautypg.com

Fil out off dflt, Db spd prs re6 re6, 854 sprayer control – TeeJet 854 Sprayer Control User Manual

Page 13

background image

www.teejet.com

8

854 Sprayer Control

Dual.Boom.Regulation.Mode

NOTE: This step will only be displayed if “Dual

Boom” was selected during the DIGITAL

OUTPUT #2 step.

Dual Boom Regulation Mode is used to regulate

the dual boom feature by either speed (SPD) or

pressure (PRS).
If speed is used to regulate the mode, when the

vehicle reaches the designated speed, the second

boom line will turn On/Off.
If pressure is used to regulate the mode, when

the pressure reaches the designated amount, the

second boom line will turn On/Off.

• Use the PLUS or MINUS keys to change

the value.

• Press the PROGRAM key to accept the

value and advance to the next program step.

The value selected will determine how programming

steps appear during System Setup Mode. Specific

speed or pressure values to be used during

operation are selected during the System Setup

Mode.
Figure 3-12: Dual Boom Regulation Mode - Speed

db

db

SPd

PrS

re6

re6

Figure 3-13: Dual Boom Regulation Mode - Pressure

db

db

SPd

PrS

re6

re6

Fill.Valve.Default

NOTE: This step will only be displayed if “Dual

Boom” was selected during the DIGITAL

OUTPUT #2 step.

The Fill Valve Default establishes the normal

operating state of the fill valve being used. If the fill

valve requires a +12v signal during the spraying

operation, the valve default is “On”. If the fill valve

requires a +12v signal during the filling operation,

the valve default is “Off”.

• Use the PLUS or MINUS keys to change

the value.

• Press the PROGRAM key to accept the

value and advance to the next program step.

Figure 3-14: Fill Valve Default

FiL OUt

OFF

dFLt