Re6 145 prs hi, Yes aud alrm, Spd db off 6.0 – TeeJet 854 Sprayer Control User Manual
Page 36: Db 15 prs, 854 sprayer control
www.teejet.com
31
854 Sprayer Control
Figure 4-45: Maximum Pressure Setting
re6
145
PrS
Hi
Audible.Alarm
The audible alarm is used to alert the operator to
problems with the sprayer control system. It is used
in addition to visual alarms on the LCD display and
LED sensor alarms above the screen.
• Use the PLUS or MINUS keys to select
“YES” to activate the audible alarm.
• Use the PLUS or MINUS keys to select
“NO” to deactivate the audible alarm.
• Press the PROGRAM key to advance to the
next step.
Audible alarms are divided into three priorities:
• Low - a long beep
• Medium - a steady beep
• High - three short beeps
Figure 4-46: Audible Alarm
YES
Aud
ALrM
Dual.Boom.On.Setting
NOTE: This step will not be displayed unless the
dual boom option was selected in the OEM
Programming Mode.
The dual boom option is the speed or pressure
at which the second boom is SHUT OFF. As the
vehicle slows, the system pressure will begin to
drop, eventually to a point where the spray tips are
no longer able to develop a pattern. The Dual Boom
On setting should be adjusted to shut off the second
boom line before this condition occurs.
• Use the PLUS or MINUS keys to adjust
the setting.
• Press the PROGRAM key to advance to the
next step
Figure 4-47: Regulating Mode - Speed
Spd
DB
OFF
6.0
Figure 4-48: Regulating Mode - Pressure
Db
15
PRs