On ext rate use, Spd 6.0 lo sim, Spd 9.0 high sim – TeeJet 854 Sprayer Control User Manual
Page 34: 854 sprayer control
![background image](/manuals/713582/34/background.png)
www.teejet.com
29
854 Sprayer Control
Figure 4-40: External Rate
ON
EXT
rate
USe
Simulated.Ground.Speed
Simulated ground speed allows the verification of
console functions and the sprayer without actually
moving the sprayer. This should be tested prior to all
spraying activity.
The 854 has a low and high simulated ground speed
that allows for switching between the two to simulate
a speed change. This will ensure that the console is
regulating properly during sprayer checkout.
To activate the simulated speed, while in the normal
operating mode with the Master Switch “On”:
• Press the PROGRAM and MINUS keys
for low simulated speed.
• Press the PROGRAM and PLUS keys for
high simulated speed.
Low Speed
• Use the PLUS or MINUS keys to adjust
value.
• Press the PROGRAM key to advance to the
High Simulated Speed step.
Figure 4-41: Low Speed Simulation
MPH
SPd
6.0
LO
SIM
High Speed
• Use the PLUS or MINUS keys to adjust
value.
• Press the PROGRAM key to advance to
High Simulated Speed step.
Figure 4-42: High Speed Simulation
MPH
SPd
9.0
High
SIM
NOTE: Once the sprayer begins moving and the
854 receives actual speed pulses, simulated
speed is deactivated. If a Radar Speed
Sensor is being used, disconnect the Radar
from the main console. Due to the sensitivity
of this speed sensor, any movement can
disable simulated speed.