6pm re6 cap 32, 10 re6 spd coar, 854 sprayer control – TeeJet 854 Sprayer Control User Manual
Page 27: Regulating.valve.capacity, Regulating.valve.speed.-.coarse. adjustment

www.teejet.com
22
854 Sprayer Control
Regulating.Valve.Capacity
Enter the maximum flow capacity of the regulating
valve in Gallons Per Minute (GPM). The valve
parameters needed to drive the regulating valve
smoothly depend on the size of the valve.
• Use the PLUS or MINUS keys to adjust
the valve so that it matches the maximum flow
capacity (GPM) of the regulating valve being
used.
• Press the PROGRAM key to advance to the
next step.
Figure 4-22: Regulating Valve Capacity
6PM
re6
CAp
32
Common Regulating Valves:
Valve
GPM
344AE-2RL
27 GPM
344AE-2RB
30 GPM
344AE-2PR
12 GPM
AA346ZR
85 GPM
AA346ZRB
85 GPM
Regulating.Valve.Speed.-.Coarse.
Adjustment
This step allows for the adjustment of the pressure
regulating valve speed to accommodate different
application needs. Operating conditions may
necessitate a higher or lower response speed for the
regulating valve.
The coarse adjustment controls the speed of the
valve when large adjustments in flow are required by
the controller.
• Use the PLUS or MINUS keys to
increase or decrease the response time.
Any number between 0 - 19 can be selected.
0 = slow
19 = fast
If the regulating valve is plumbed in a bypass line,
the valve speed coarse adjustment number of “15”
works well in most applications.
If the regulating valve is plumed in the Throttling
position (supply line) start with a coarse adjustment
speed number of “5” and adjust the number
according to application requirements.
• Press the PROGRAM key to accept the
value and advance to the next step.
Figure 4-23: Coarse Adjustment
10
re6
spd
COAr