beautypg.com

Status of doors table (continued) – Keri Systems TAP100 User Manual

Page 77

background image

TAP100 Application Software Manual

Revision 3.3

Page 77

Status of Doors Table (continued)

Hexadecimal Digit

Hexadecimal Value

Binary Value

Active Readers

xxXx xxxx

if X is a . . .

its value is . . .

indicating the secired doors are . . .

0

0000

24, 23, 22, and 21

1

0001

24, 23, and 22

2

0010

24, 23, and 21

3

0011

24 and 23

4

0100

23, 22, and 21

5

0101

24 and 22

6

0110

24 and 21

7

0111

24

8

1000

23, 22, and 21

9

1001

23 and 22

A

1010

23 and 21

B

1011

23

C

1100

22 and 21

D

1101

22

E

1110

21

F

1111

doors 24, 23, 22, and 21 are not secured

xXxx xxxx

if X is a . . .

its value is . . .

indicating the secured doors are . . .

0

0000

28, 27, 26, and 25

1

0001

28, 27, and 26

2

0010

28, 27, and 25

3

0011

28 and 27

4

0100

28, 26, and 25

5

0101

28 and 26

6

0110

28 and 25

7

0111

28

8

1000

27, 26, and 25

9

1001

27 and 26

A

1010

27 and 25

B

1011

27

C

1100

26 and 25

D

1101

26

E

1110

25

F

1111

doors 28, 27, 26, and 25 are not secured

Xxxx xxxx

if X is a . . .

its value is . . .

indicating the secured doors are . . .

0

0000

32, 31, 30, 29

1

0001

32, 31, and 30

2

0010

32, 31, and 29

3

0011

32 and 31

4

0100

32, 30, and 29

5

0101

32 and 30

6

0110

32 and 29

7

0111

32

8

1000

31, 30, and 29

9

1001

31 and 30

A

1010

31 and 29

B

1011

31

C

1100

30 and 29

D

1101

30

E

1110

29

F

1111

doors 32, 31, 30, and 29 are not secured