Disable global lock/unlock, Table 2 - automatic lock/unlock state – Keri Systems TAP100 User Manual
Page 69

TAP100 Application Software Manual
Revision 3.3
Page 69
Once communication is complete, the global lock/unlock function has been enabled.
Disable Global Lock/Unlock
The disable global lock/unlock (GLU) function disables the ability for an external device to
automatically lock or unlock all readers on the network at one time.
Disabling the GLU feature from the enabled state while a global unlock is in force will immediately
lock all doors and then restore the doors to the appropriate automatic lock/unlock (ALU) state
(see Table 2 to determine the appropriate ALU state).
Regardless of if the GLU command is enabled or disabled, every state change at the GLU input is
logged and forwarded to the host.
To disable the global lock/unlock function, use your pointing device and select Readers and then
Disable global lock/unlock. The Status Message Line will display:
Once communication is complete, the global lock/unlock function has been disabled.
Table 2 - Automatic Lock/Unlock State
ALU STATE
LOCK STATE
EVENT
PXL-100 ACTION
STATE
CHANGES
Lock Command
no action
LOCKED
Unlock Command
unlock door
SUSPEND,
UNLOCKED
Global Secure Time
no action
ON
Lock Command
lock door
SUSPEND,
LOCKED
UNLOCKED
Unlock Command
no action
Global Secure Time
no action
Lock Command
no action
LOCKED
Unlock Command
unlock door
Global Secure Time
no action
OFF
Lock Command
lock door
UNLOCKED
Unlock Command
no action
Global Secure Time
lock door
Lock Command
no action
LOCKED
Unlock Command
unlock door
ON, UNLOCKED
Global Secure Time
ON
SUSPEND
Lock Command
lock door
ON, LOCKED
UNLOCKED
Unlock Command
no action
Global Secure Time
ON
Initiating communication with local network on COM1 . . . please wait.