PROG
Progressive setting
Format
PROG=
Parameter
Errors supported by model
Parameter
Meaning
SX50
SX6, SX60, X600
SX7, X700
SX7 Mark II
0 OFF ○
○
○
○
1 ON ○
○
○
○
2 AUTO x
○
○
○
The parameters which can be set at any given point in time can be obtained using the
RANGE command. For details, refer to the RANGE command.
Response
"i:OK" is returned if the parameter was set properly.
For details on other responses, refer to the "Error List".
Description
This command is used to set the progressive conversion processing to ON or OFF.
(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and
power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.
(2) A “busy” response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
(3) It may not be possible to execute the command with some input signals.
(4) This command is the same as the menu functions in the table below.
Model
Menu
SX50
[Image adjustments] - [Progressive]
SX6, SX60, X600, SX7, X700,
SX7 Mark II
[Display settings] - [Progressive]
(5) This sets the currently selected input signal and image mode.
(6) The menu display statuses are as listed in the table below by model.
Model
Menu display statuses, etc.
SX50
If the input signals are "Component" signals of any of the following types, the
signals cannot be processed even when "ON" has been selected as the
progressive conversion setting to perform progressive conversion.
・
1080i ・720p ・480p ・1035i ・575p
SX6, SX60, X600, SX7, X700,
SX7 Mark II
When signals from a progressive source have been input, the progressive
conversion setting can be selected, but the field will be blank on the menu. If
the input signals are "Component" signals of any of the following types, the
signals cannot be processed even when "ON" or "AUTO" has been selected
as the progressive conversion setting to perform progressive conversion, but
the value on the menu will change. However, the value will be grayed out.
・1080i ・720p ・480p ・1035i ・575p
Reference
・
1080i ・720p ・480p
・
1035i ・575p
With the SX50, IP_NOT_AVAILABLE is returned for both referencing and
setting in response to the signals on the left.
(7) The GET command can be used to retrieve the current value The significance of the acquired values is
given in the table below.
For details, refer to the GET command.
Model
Significance of acquired value
SX50
Current progressive conversion processing status
(1: conversion underway, 0:no conversion)
SX6, SX60, X600, SX7, X700,
SX7 Mark II
Setting currently established for progressive conversion
Setting