Get lmpt, Projector user commands, Format – Canon SX 50 User Manual
Page 150: Response, Description, Example, Commands supported, Environment
Projector User Commands
- 144 -
Revision History / Date
Changes
Revised by
Approved by
GET LMPT
Lamp lighting time inquiry
Format
GET□LMPT
?△LMPT
Response
g:LMPT=
For details on other responses, refer to the "Error List".
Description
This command is used to inquire about the lamp lighting time.
(1) This inquiry can be made in any status provided that AC power is supplied to the projector.
(2) Range of values is 0 hour 0 minute to 65535 hours 59 minutes.
Example
> GET LMPT or ? LMPT
< g:LMPT=123:45
Lamp lighting time is 123 hours 45 minutes
* Commands are indicated by ">", and responses are indicated by "<".
Commands supported
This defines the environments that support the command (power supply state, input signal state).
SX50
01.00**
SX6
01.01**
SX60
01.01**
X600
01.01**
SX7
01.01**
X700
01.01**
SX7 Mark II
01.02**
x x x x x x O
* When a command is not supported, "e:000A INVALID_PARAMETER" is returned.
Environment
This defines the environments that support the command (power supply state, input signal state).
Power
Input
Mode
Model
OFF ON PM
D-RGB A-RGB1 A-RGB2 COMP
Video S-Video D-Video SCART None Remote Local
Remarks
SX50 -
-
- - - - - - - - - - - -
SX6, SX60,
X600
-
-
- - - - - - - - - - - -
SX7,
X700
-
-
- - - - - - - - - - - -
SX7 Mark II O
O O
O
O
O
O
O
O
O
O
O
O
O
* If a state is not supported, "INVALID_MODE" is returned with the Err response.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.