LEDILLUMINATE
Emotional LED and signal sensing LED lighting control
Format
LEDILLUMINATE=
Parameter
ON
This sets the LED display to ON.
OFF
This sets the LED display to OFF.
The parameters which can be set at any given point in time can be obtained using the RANGE
command. For details, refer to the RANGE command.
Response
"i:OK" is returned if the parameter was set properly.
For details on other responses, refer to the "Error List".
Description
This command is used to control the lighting of the emotional LED and signal sensing LED.
(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and
power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.
(2) A “busy” response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
(3) This command functions in the same way as when "System setting" - "LED illumination" are selected on
the menu.
(4) The GET command can be used to retrieve the current LED illumination setting.
For details, refer to the GET command.
Example
Setting
> LEDILLUMINATE=ON
The LED display is set to ON.
< i:OK
Reference
> GET LEDILLUMINATE or ?LEDILLUMINATE The ON or OFF setting for the LED display is obtained.
< g:LEDILLUMINATE=ON
Acquisition of parameters which can be set
> RANGE LEDILLUMINATE
< r:LEDILLUMINATE=I, ON, OFF
"ON" or "OFF" can be set for the LED display.
* Commands are indicated by ">", and responses are indicated by "<".
Commands supported
This defines the environments that support the command (power supply state, input signal state).
SX50
01.00**
SX6
01.01**
SX60
01.01**
X600
01.01**
SX7
01.01**
X700
01.01**
SX7 Mark II
01.02**
x O O O O O O
* When a command is not supported, "e:0002 INVALID_COMMAND" is returned.
Environment
This defines the environments that support the command (power supply state, input signal state).
Power
Input
Mode
Model
OFF ON PM
D-RGB A-RGB1 A-RGB2 COMP
Video S-Video D-Video SCART None Remote Local
Remarks
SX50 -
-
- - - - - - - - - - - -
SX6, SX60,
X600
x
O
x
O
O
O
O
O
O
O
O
O
O
x
SX7, X700
x
O
x
O
O
O
O
O
O
O
O
O
O
x
SX7 Mark II
x
O
x
O
O
O
O
O
O
O
O
O
O
O
* If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.
Setting