beautypg.com

Get comver, Projector user commands, Format – Canon SX 50 User Manual

Page 128: Response, Description, Example, Commands supported, Environment

background image

Projector User Commands


- 122 -

Revision History / Date

Changes

Revised by

Approved by

GET COMVER

User command version inquiry

Format

GETCOMVER
?
COMVER

Response

g:COMVER="Character string>"

:= 99.9999
For details on other responses, refer to the "Error List".

Description

This command is used to inquire about the user command version of the projector.

(1) This inquiry can be made in any status provided that AC power is supplied to the projector.

For the "SX50," the remote mode must be established.

(2) The user command version consists of a 2-digit number followed by a 4-digit number. Question marks may

appear in place of the numerals if the firmware has not been upgraded correctly.
(Example "??:????")

Example

> GET COMVER or ? COMVER

< g:COMVER="01.0000"

* Commands are indicated by ">", and responses are indicated by "<".

Commands supported

This defines the environments that support the command (power supply state, input signal state).

SX50

01.00**

SX6

01.01**

SX60

01.01**

X600

01.01**

SX7

01.01**

X700

01.01**

SX7 Mark II

01.02**

O O O O O O O

Environment

This defines the environments that support the command (power supply state, input signal state).

Power

Input

Mode

Model

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

Video S-Video D-Video SCART None Remote Local

Remarks

SX50 O

O

O O O

O

O O

O

- - O O x

SX6, SX60,

X600

O

O O

O

O

O

O

O

O

O

O

O

O

O

SX7, X700 O

O

O

O

O

O

O

O

O

O

O

O

O

O

SX7 Mark II O

O O

O

O

O

O

O

O

O

O

O

O

O

* If a state is not supported, "INVALID_MODE" is returned with the Err response.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.

Reference