beautypg.com

Range ledilluminate, Projector user commands, Format – Canon SX 50 User Manual

Page 208: Response, Description, Example, Commands supported, Environment

background image

Projector User Commands


- 202 -

Revision History / Date

Changes

Revised by

Approved by

RANGE LEDILLUMINATE

Emotional LED and signal sensing LED lighting setting option request

Format

RANGELEDILLUMINATE

Response

r:LEDILLUMINATE=I, , , …,

For details on other responses, refer to the "Error List".

Description

This command is used to inquire about the parameter options which enable emotional LED and signal sensing
LED lighting control to be set.

(1) For models other than SX7 Mark II: Inquiry can be made when the projector is in both the remote mode

and power-on status at the same time.
For SX7 Mark II: Inquiry can be made whenever the projector is in the power-on status.

(2) A “busy” response is given while the zoom or focus lens is being driven.

(Refer to the ZCONTDRV command and FCONTDRV command.)

(3) LED lighting control can be set using the LEDILLUMINATE command.

Example

> RANGE LEDILLUMINATE

< r:LEDILLUMINATE=I, ON, OFF

* Commands are indicated by ">", and responses are indicated by "<".

Commands supported

This defines the environments that support the command (power supply state, input signal state).

SX50

01.00**

SX6

01.01**

SX60

01.01**

X600

01.01**

SX7

01.01**

X700

01.01**

SX7 Mark II

01.02**

x O O O O O O

* When a command is not supported, "e:000A INVALID_PARAMETER" is returned.

Environment

This defines the environments that support the command (power supply state, input signal state).

Power

Input

Mode

Model

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

Video S-Video D-Video SCART None Remote Local

Remarks

SX50 -

-

- - - - - - - - - - - -

SX6, SX60,

X600

x

O

x

O

O

O

O

O

O

O

O

O

O

x

SX7, X700

x

O

x

O

O

O

O

O

O

O

O

O

O

x

SX7 Mark II x

O

x

O

O

O

O

O

O

O

O

O

O

O

* If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response.