Error list, Projector user commands – Canon SX 50 User Manual
Page 233
Projector User Commands
- 227 -
Revision History / Date
Changes
Revised by
Approved by
10. Error List
Errors supported
by model
Item Code TYPE
Error character strings
(1) (2) (3) (4)
Error
Remedy
1 0001 e BAD_SEQUENCE
O O
O
O Communication
sequence
error.
Wait until a response is received before
sending the next command.
2
0002
e
INVALID_COMMAND
O O
O
O Invalid (undefined) command.
Send a valid command.
3 0003 e INVALID_MODE
O O
O
O
The designated command cannot be
executed in this mode.
Switch the mode using the REMOTE or
LOCAL command.
4 0004 e INVALID_FORMAT
O O
O
O Invalid command format.
Send the command in the valid format.
5
0005
e
NOT_POWER_SUPPLIED
O O
O
O The projector's power is off.
Turn on the power using the POWER ON
command.
6 - i
BUSY
O
O
O
O
Mode switching or processing inside the
projector is underway.
Wait until the power supply state
changes to ON, OFF or PMM.
7 000A e INVALID_PARAMETER
O O
O
O
The parameter (type) is invalid
(undefined).This includes the case when
the number of parameters is incorrect.
Use the correct parameter(s).
8 000B e JOB_TIMEOUT
O O
O
O
I
nternal processing of the projector has
timed out.
Resend the command.
9 - w
USER_COMMAND_VERSION_
IS_UPDATED
O O
O
O
The user command version is being
updated.
Use GET COMVER to obtain the latest
user command version.
i
BUSY (FOCUS)
O
O
O The focus lens is now being driven.
Wait until the focus lens drive stops.
10 -
i
BUSY (ZOOM)
O
O
O The zoom lens is now being driven.
Wait until the zoom lens drive stops.
F001
e
SYSTEM (UNKNOWN)
O O
O
O An internal error occurred.
Resend the command.
F002 e SYSTEM
(FOCUS)
O
O
O
An error occurred in
AUTOSETEXE=FOCUS.
F004 e SYSTEM
(AUTO_KEYSTONE) O
O
O
An error occurred in
AUTOSETEXE=VKS.
11
F005 e SYSTEM
(SCREEN_COLOR) O
O
O
An error occurred in
AUTOSETEXE=SCRN.
Eliminate the cause of the error, and
resend the command.
12 E0XX e COMMUNICATION_ERROR O O
O
O
A communication protocol violation
occurred in the projector.
Resend the command.
13 1008 e NOT_SUPPORTED_ASPECT
O
Specified aspect cannot be set since the
screen aspect is not 4:3.
Use the range command to obtain an
addressable parameter range to be set
for ASPECT.
14 1008 e INVALID_SCREEN_ASPECT
O
It cannot be executed due to current
screen aspect setting.
Change the screen aspect setting.
15 200X e INVALID_SOURCE
(****)
O O
O
O
It cannot be executed with the current
input source. Current input source is
shown in brackets.
Change the input source.
2010
e
NO_SIGNAL
O O
O
O There is no signal input.
Input the signal.
16
201X e INVALID_SIGNAL
O O
O
O
It cannot be executed with the current
input signal. Current input signal is
shown in brackets.
Change the input signal.
i
BUSY (NOW_SETTING)
O O
O
O Signal setting (detection) is in progress.
i
BUSY
(POWER_MANAGEMENT_RE
ADY)
O O
O
O
Preparing to switch to power
management standby.
17 -
i BUSY
(INTERNAL_PROCESS)
O O
O
O Heavy processing is in progress.
Wait until the processing is completed.
18
0801
0802
e INVALID_VALUE
O O
O
O
Numerical parameters are invalid or
outside the range.
Use the RANGE command to obtain the
parameter range, and then use a
parameter within the range.
1001 e TERMINAL_OUT
O
The input cannot be selected since the
terminal is set to output.
Use the TERMINAL command to set the
terminal to input, and then select the
input again.
1002 e NO_LOGO_CAPTURED
O O
O
Processing cannot be executed since the
user image is not registered.
Register the user image.
1003 e IP_NOT_AVAILABLE
O O
O
O IP
conversion
cannot
be performed.
Change to the correct input signal.
1004 e POWER_MANAGEMENT_OFF O
O
O
DPON cannot be set to ON when PMM is
OFF.
Set DPON to anything other than OFF.
1005 e DIRECT_POWER_ON
O
O
O
PMM cannot be set to OFF when DPON
is ON.
Set DPON to OFF.
1006 e NOW_BLANK
O
O
O
AUTOSETEXE=FOCUS or SCRN
cannot be executed since BLANK is ON.
After setting BLANK to OFF, resend the
command.
19
203X
e
INVALID_RESOLUTION (***)
O O
O
O The input signal resolution is not correct.
Change to the correct resolution of the
input signal.
20 - i
INPUT_NOT_FOUND
O
O
O
The input was not switched since no
input signal was found with
AUTOSETEXE=INPUT.
There is no action to be taken since the