Autopc, Projector user commands, Format – Canon SX 50 User Manual
Page 31: Response, Description, Example, Commands supported, Environment
Projector User Commands
- 25 -
Revision History / Date
Changes
Revised by
Approved by
AUTOPC
Auto PC
Format
AUTOPC
Response
"i:OK" is returned if the control was executed properly.
For details on other responses, refer to the "Error List".
Description
This executes Auto PC.
(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and
power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.
(2) A “busy” response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
(3) It may not be possible to execute the command with some input signals.
(4) This command is identical to pressing the “AUTOPC” button on the remote control.
(5) Execution of this command may modify the following setting values.
・
Total number of dots
・
Tracking
・
Horizontal/vertical positions
・
Number of horizontal/vertical display dots
(6) To confirm modified setting values, use the GET command of the respective parameter.
(7) For details, refer to the GET commands below.
Setting
GET
Total number of dots
GET DOTS
Tracking
GET TRACK
Horizontal position
GET HPOS
Vertical position
GET VPOS
Number of horizontal display dots
GET HPIX
Number of vertical display dots
GET VPIX
Example
> AUTOPC
< i:OK
* Commands are indicated by ">", and responses are indicated by "<".
Commands supported
This defines the environments that support the command (power supply state, input signal state).
SX50
01.00**
SX6
01.01**
SX60
01.01**
X600
01.01**
SX7
01.01**
X700
01.01**
SX7 Mark II
01.02**
O O O O O O O
Environment
This defines the environments that support the command (power supply state, input signal state).
Power
Input
Mode
Model
OFF ON PM
D-RGB A-RGB1 A-RGB2 COMP
Video S-Video D-Video SCART None Remote Local
Remarks
SX50 x
O
x x O
O
x x x - - x O x
SX6, SX60,
X600
x
O
x x O
O
x x x x x x O x
SX7,
X700
x
O
x x O
O
x x x x x
x O x
SX7 Mark II x
O
x x O
O
x x x x x x O O
* If a state is not supported, "INVALID_MODE", "NOT_POWER_SUPPLIED" or “INVALID_SOURCE” is returned with the Err
response.
* If the necessary signals are not input, 'INVALID_SIGNAL (*****)' or 'NO_SIGNAL' is returned.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.
Control