beautypg.com

Dots – Canon SX 50 User Manual

Page 43

background image

Projector User Commands


- 37 -

Revision History / Date

Changes

Revised by

Approved by

DOTS

Total number of dots adjustment

Format

DOTS=

Parameter

Number of dots

The RANGE command can be used to obtain the parameter range that can be set at that time.
For details, refer to the RANGE command.

Response

"i:OK" is returned if the parameter was set properly.
For details on other responses, refer to the "Error List".

Description

This designates the total number of dots for one horizontal period.

(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and

power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.

(2) A “busy” response is given while the zoom or focus lens is being driven.

(Refer to the ZCONTDRV command and FCONTDRV command.)

(3) It may not be possible to execute the command with some input signals.
(4) This command is the same as the menu functions in the table below.

Model

Menu

SX50

[Display settings] - [Input signal settings] - [Total number of dots adjustments]

SX6, SX60, X600, SX7, X700,
SX7 Mark II

[Display settings] - [Input signal settings] - [Total number of dots]

(5) The GET command can be used to retrieve the current total number of dots.

For details, refer to the GET command.

Example

Setting

> DOTS=1650

The total number of dots is 1650.

< i:OK

Reference

> GET DOTS or ?DOTS

This retrieves the total number of dots.

< g:DOTS=1200

Obtain settable parameter range (Min, Max)

> RANGE DOTS

< r:DOTS=N, 0, 4096

Any value from 0 to 4096 can be set for the total dots.

* Commands are indicated by ">", and responses are indicated by "<".

Commands supported

This defines the environments that support the command (power supply state, input signal state).

SX50

01.00**

SX6

01.01**

SX60

01.01**

X600

01.01**

SX7

01.01**

X700

01.01**

SX7 Mark II

01.02**

O O O O O O O

Setting