beautypg.com

Warning, Residential garage installations, Boiler freeze protection feature – AERCO Esteem O&M Manual User Manual

Page 12: Gf-125

background image

66

N

OTICE

When maintaining zero clearance or
less than recommended clearances,
some product labeling may become
hidden and unreadable.

WARNING

W

HEN

INSTALLING

THE

E

STEEM

399 L

OW

NO

X

IN

A

CONFINED

SPACE

,

SUFFICIENT

AIR

MUST

BE

PROVIDED

FOR

PROPER

COMBUSTION

AND

VENTING

AND

TO

ALLOW

,

UNDER

NORMAL

OPER

-

ATING

CONDITIONS

,

PROPER

AIR

FLOW

AROUND

THE

PRODUCT

TO

MAINTAIN

AMBIENT

TEMPERA

-

TURES

WITHIN

SAFE

LIMITS

TO

COMPLY

WITH

THE

N

ATIONAL

F

UEL

G

AS

C

ODE

NFPA 54 -

LATEST

EDITION

.

Residential Garage Installations

When installing the Esteem 399 Low NOx
in a residential garage, the following special
precautions per NFPA 54/ANSI Z223.1 must
be taken:

• Mount the unit a minimum 18 inches

[458 mm] above the floor level of the
garage. Ensure the burner and ignition
devices / controls are no less than 18
inches [458 mm] above the floor level.

• Locate or protect the unit in a manner

so it cannot be damaged by a moving
vehicle.

Boiler Freeze Protection Feature

The boiler control has a freeze protection fea-
ture built in. This feature monitors the boiler
temperature and responds as follows when no
call for heat is present:

• 46ºF Boiler circulator is ON

• 38ºF Boiler circulator is ON and burner

operates at low fire

• 50ºF Burner OFF and boiler circulator

operates for approximately 10 minutes

C

AUTION

The boiler freeze protection feature is
disabled during a hard lockout, how-
ever the space heating circulator will
operate.

C

AUTION

The boiler freeze protection feature
is designed to protect the boiler. The
boiler should be installed in a primary/
secondary piping arrangement if it is
installed in an unheated space or ex-
posed to water temperatures of 46ºF or
less. See “Chapter 5 Boiler Piping” on
page 16 for primary/secondary piping ex-
amples. See Chapter 10 for antifreeze
guides.

GF-125

GF-125