4 command parameter list, Comm u nic a ti ng w it h th e sk-1 000 se ri es – KEYENCE DL-CL1 User Manual
Page 60

3-4 Command Parameter List
3-32
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
Comm
u
nic
a
ti
ng
w
it
h th
e
SK-1
000 Se
ri
es
3
*1
The error content of the sensor amplifier can be checked by noting the ON/OFF
state of each bit.
OFF (0): No error; ON (1): Error
More than one error may occur simultaneously. For details of each error, refer to
the SK-1000 Series Instruction Manual.
*2
Details of output status can be checked by noting the ON/OFF state of each bit.
00
nn94
External input 3
*15
R/W
0
0: Timing input
1: Bank A input
2: Bank B input
3: Not use
nn95
External input 4
*15
R/W
4
0: Bank A input
1: Bank B input
2: Not use
nn96
Bank switching method
R/W
0
0: Button
1: External input
nn97
Reserved
nn98
Zero shift value memory
function
R/W
0
0: OFF
1: ON
nn99
Reserved
nn9A
Display digit
R/W
0
0: Initial state
1: 0.001
2: 0.01
3: 0.1
4: 1
nn9B to
nn9F
Reserved
nnA0
Group-5 entry count
R
4
nnA1
Distance correction method
R/W
0
0: Initial state
1: User setting
nnA2
Near-side distance correction
amount
R/W
25
5 to 50
nnA3
Far-side distance correction
amount
R/W
100
60 to 120
nnA4
Area scaling
R/W
1.00
0.10 to 1.50
nnA5 to
nnBF
Reserved
nnC0
Group6 Entry count
R
11
nnC1
Product code
R
Main unit: 4024
Expansion unit: 4025
nnC2
Reserved
nnC3
Connected sensor head
R
0
0: Not connected
1: The head is connected
nnC4 to
nnC7
Reserved
nnC8
Product name 1
*18
R
Main unit: "SK-1"
Expansion unit: "SK-1"
nnC9
Product name 2
*18
R
Main unit: "000/"
Expansion unit: "050/"
nnCA
Product name 3
*18
R
Main unit: ""
Expansion unit: ""
nnCB
Product name 4
*18
R
Main unit: ""
Expansion unit: ""
nnCC to
nnFF
Reserved
Data
category
(Hex)
Data
number
(Hex)
Name
Description
Attribute
Default
value
Parameter description