3 communication methods, Comm u nic a ti ng w it h th e sk-1 000 se ri es – KEYENCE DL-CL1 User Manual
Page 47

3-3 Communication Methods
3-19
3
Comm
u
nic
a
ti
ng
w
it
h th
e
SK-1
000 Se
ri
es
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
Judgment values (P.V. values) can be read in the monitor modes and full modes.
They cannot be read in small-memory modes.
Monitor mode 1
When reading judgment values (P.V. values) in monitor mode 1, specify the ID
numbers (in terms of judgment value page numbers) of the sensor amplifiers to be
read to judgment value boxes 1 to 3. For details of the judgment value box numbers
and judgment value page numbers used for specifying ID numbers, see
When reading judgment values in monitor mode 2 or full mode, see
mode 2/full mode" (page 3-20).
This example illustrates how to read the judgment values (P.V. values) from the sensor amplifiers of ID
01/02/03 and ID 04.
(1) Specify the page numbers in "select judgment value box page number" and execute "request to
change judgment value page".
(2) After the judgment values of the specified judgment value pages are read, the "judgment value page
change complete" signal flips from 0 to 1.
(3) The "judgment value page change error" signal flips from 0 to 1 if an error occurs during the
judgment value change process. Check the values specified in the "select judgment value box page
number" parameter.
(4) The property of each judgment value is entered. Check that each judgment value is normal value,
"over," "under," or "invalid."
Reading Judgment Values (P.V. Values) from Sensor Amplifiers
PLC
Sensor amplifier
Select comparator value box page number 0 (Comparator value page 0)
2 (Comparator value page 2)
RWw08
Request to change comparator value page
RY5E
(2)
Comparator value page change complete
RX5E
(3)
Comparator value page change error
RX5F
(4)
Comparator value property
Each bit of RWr07
(5)
Comparator value box 1 1234
8901
5678
RWr08
Comparator value box 2 2345
9012
6789
RWr0A
Comparator value box 3 3456
7890
RWr0C
(7)
Comparator value of ID 01 1234
8901
(7)
Comparator value of ID 02 2345
9012
Comparator value of ID 03 3456
Comparator value of ID 04
5678
1
1
1
1
0
0
0
0
(1)
(6)