KEYENCE DL-CL1 User Manual
Page 20

2-1 Installation and Connection to Sensor Amplifiers
2-4
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
2
Connec
ti
on and
Conf
ig
u
ration
Procedures for connecting to sensor amplifiers
The CC-Link compatible communication unit DL-CL1 must be connected to sensor
amplifiers before it can provide its function.
The connecting procedure varies with the mounting type of the sensor amplifiers to be
connected.
For the instructions on connecting additional sensor amplifiers, refer
to the instruction manual of the sensors amplifiers.
Connecting to sensor amplifiers of DIN rail mounting type
1
Remove the expansion protective cover from the sensor amplifier to be
connected.
2
Install the CC-Link compatible communication unit DL-CL1 on the DIN rail
and connect to the sensor amplifier.
Ensure a tight connection, leaving no space between the CC-Link compatible
communication unit DL-CL1 and the sensor amplifier.
Make sure that the power to the sensor amplifier is off before starting to
connect the CC-Link compatible communication unit DL-CL1. Perform-
ing the procedure with the power on may damage the DL-CL1.
NOTICE
Point
Sensor amplifier
Expansion protective cover
Sensor amplifier
CC-Link compatible
communication unit DL-CL1
Connector