2 device maps, Comm u nic a ti ng w it h th e sk-1 000 se ri es – KEYENCE DL-CL1 User Manual
Page 41

3-2 Device Maps
3-13
3
Comm
u
nic
a
ti
ng
w
it
h th
e
SK-1
000 Se
ri
es
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
Number [n] denotes the first relay number assigned to the DL-CL1.
*1
Refer to
"Reading an Output from a Sensor Amplifier" (page 3-18).
*2
Refer to
*3
Refer to
"Changing the BANK Number of Sensor Amplifiers" (page 3-21).
*4
Refer to
"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-23).
*5
Refer to
"Issuing a Motion Command to a Sensor Amplifier" (page 3-22).
Mo
nito
r mo
de
2
F
u
ll mo
de
1
F
u
ll mo
de
2
RX[n] + 60
to 67
BANK change
complete ID 01
to ID 08
*3
Used when changing BANK
number.
This is output when BANK number
has been changed.
The output of each sensor
amplifier (ID 01 to ID 08)
corresponds to each RX.
0->1: Change
complete
RX[n] + 6F
BANK change
error
*3
Used when changing BANK
number.
This is output if an error occurs
with a sensor amplifier of any ID
number during BANK number
changing.
0: No error
1: Error
RX[n] + 70
to 77
HI setting value
(BANK 0)
rewrite
complete ID 01
to ID 08
*5
Used when rewriting a setting
value.
This is output when the HI setting
value (BANK 0) has been
changed.
The output of each sensor
amplifier (ID 01 to ID 08)
corresponds to each RX.
0->1: Rewrite
complete
RX[n] + 7F
HI setting value
(BANK 0)
rewrite error
*5
Used when rewriting a setting
value.
This is output if an error occurs
with a sensor amplifier of any ID
number during rewriting of HI
setting value (BANK 0).
0: No error
1: Error
RX[n] + 80
to 87
LO setting
value (BANK 0)
rewrite
complete ID 01
to ID 08
*5
Used when rewriting a setting
value.
This is output when the LO setting
value (BANK 0) has been
changed.
The output of each sensor
amplifier (ID 01 to ID 08)
corresponds to each RX.
0->1: Rewrite
complete
RX[n] + 8F
LO setting
value (BANK 0)
rewrite error
*5
Used when rewriting a setting
value.
This is output if an error occurs
with a sensor amplifier of any ID
number during rewriting of LO
setting value (BANK 0).
0: No error
1: Error
RX[n] + 7B
Remote ready
-
This is output when the DL-CL1 is
correctly connected to the CC-Link
system.
1: Proper communication is
provided. Data from the sensor
amplifier will be updated.
0: Proper communication is not
provided. Data from the sensor
amplifier will not be updated.
0: In preparation
1: Ready
RX[n] + DB
RX[n] + 17B
Operating
mode
Device no.
(HEX)
Name
Communication
method
Description
Reading range