2 device maps, Comm u nic a ti ng w it h th e sk-1 000 se ri es – KEYENCE DL-CL1 User Manual

Page 41

background image

3-2 Device Maps

3-13

3

Comm

u

nic
a

ti

ng

w

it

h th

e

SK-1

000 Se

ri

es

- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -

Number [n] denotes the first relay number assigned to the DL-CL1.

*1

Refer to

"Reading an Output from a Sensor Amplifier" (page 3-18).

*2

Refer to

"Monitor mode 1" (page 3-19).

*3

Refer to

"Changing the BANK Number of Sensor Amplifiers" (page 3-21).

*4

Refer to

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-23).

*5

Refer to

"Issuing a Motion Command to a Sensor Amplifier" (page 3-22).

Mo

nito

r mo

de
2

F

u

ll mo

de
1

F

u

ll mo

de
2

RX[n] + 60
to 67

BANK change
complete ID 01
to ID 08

*3

Used when changing BANK
number.
This is output when BANK number
has been changed.
The output of each sensor
amplifier (ID 01 to ID 08)
corresponds to each RX.

0->1: Change
complete

RX[n] + 6F

BANK change
error

*3

Used when changing BANK
number.
This is output if an error occurs
with a sensor amplifier of any ID
number during BANK number
changing.

0: No error
1: Error

RX[n] + 70
to 77

HI setting value
(BANK 0)
rewrite
complete ID 01
to ID 08

*5

Used when rewriting a setting
value.
This is output when the HI setting
value (BANK 0) has been
changed.
The output of each sensor
amplifier (ID 01 to ID 08)
corresponds to each RX.

0->1: Rewrite
complete

RX[n] + 7F

HI setting value
(BANK 0)
rewrite error

*5

Used when rewriting a setting
value.
This is output if an error occurs
with a sensor amplifier of any ID
number during rewriting of HI
setting value (BANK 0).

0: No error
1: Error

RX[n] + 80
to 87

LO setting
value (BANK 0)
rewrite
complete ID 01
to ID 08

*5

Used when rewriting a setting
value.
This is output when the LO setting
value (BANK 0) has been
changed.
The output of each sensor
amplifier (ID 01 to ID 08)
corresponds to each RX.

0->1: Rewrite
complete

RX[n] + 8F

LO setting
value (BANK 0)
rewrite error

*5

Used when rewriting a setting
value.
This is output if an error occurs
with a sensor amplifier of any ID
number during rewriting of LO
setting value (BANK 0).

0: No error
1: Error

RX[n] + 7B

Remote ready

-

This is output when the DL-CL1 is
correctly connected to the CC-Link
system.
1: Proper communication is
provided. Data from the sensor
amplifier will be updated.
0: Proper communication is not
provided. Data from the sensor
amplifier will not be updated.

0: In preparation
1: Ready

RX[n] + DB

RX[n] + 17B

Operating

mode

Device no.

(HEX)

Name

Communication

method

Description

Reading range