4 command parameter list, Comm u nic a ti ng w it h th e sk-1 000 se ri es – KEYENCE DL-CL1 User Manual
Page 59

3-4 Command Parameter List
3-31
3
Comm
u
nic
a
ti
ng
w
it
h th
e
SK-1
000 Se
ri
es
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
00
nn68
Sub display's screen
R/W
0
0: Temperature and humidity
1: Temperature
2: Humidity
3: HI setting value
4: LO setting value
5: RV value
nn69
System parameter settings
*11
R/W
0
Main unit: 0 - 9
Expansion unit: 0 - 1
nn6A to
nn7F
Reserved
nn80
Group-4 entry count
R
26
nn81
Reserved
nn82
Range setting
R/W
0: NEAR
1: FAR
2: Ib
nn83 to
nn84
Reserved
nn85
Averaging
R/W
5
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 64 times
6: 256 times
7: 1024 times
8: 4096 times
9: 16384 times
nn86
Output mode
R/W
0
0: N.O. (normally open)
1: N.C. (normally closed)
nn87
Reserved
nn88
Hold function setting
R/W
0
0: Sample hold
1: Peak hold
2: Bottom hold
3: Absolute value hold
4: Auto peak hold
5: Auto bottom hold
6: Auto absolute value hold
nn89
Reserved
nn8A
Timing input setting
R/W
0
0: Level
1: Edge
nn8B to
nn8C
Reserved
nn8D
Hysteresis
R/W
0.100
0.000 to 99.999
nn8E
Analog output scaling
*14
R/W
0
0: Initial state
1: Free range
nn8F
Analog output upper limit
*14
R/W
10.000
-99.999 to 99.999
nn90
Analog output lower limit
*14
R/W
-10.000
-99.999 to 99.999
nn91
External input
*15
R/W
0
0: Initial state
1: User setting
nn92
External input 1
*15
R/W
0
0: Zero shift input
1: Bank A input
2: Bank B input
3: Not use
nn93
External input 2
*15
R/W
0
0: Reset input
1: Bank A input
2: Bank B input
3: Not use
Data
category
(Hex)
Data
number
(Hex)
Name
Description
Attribute
Default
value
Parameter description