W

ArNiNgs

Please heed the following warnings related to the various types of power supplies that can be used with the F6

Modular I/O Frame.

For Power Over A-Net

When powered through the copper (Cat-5) A-Net Port B connector, the F6 Modular I/O Frame shall be connected to an

Aviom POA80 power supply, a UL60950-1 Certified/Listed ITE power supply having a SELV (Safety Extra Low Voltage)

rated output.

No other power supply should be connected to this A-Net port.

Turn off the POA80 power supply before removing or patching any Cat-5 connections.

For DC Power via the XLR or Euroblock

When powered through the Euroblock terminal block or 4-pin XLR connectors, the F6 Modular I/O Frame shall be

connected to a UL60950-1 Certified/Listed ITE power supply having a SELV (Safety Extra Low Voltage) rated output

voltage between 22 and 60V DC. To guarantee proper startup, this supply should be rated for at least 100 watts.

System Connections

The copper (RJ45) and fiber A-Net ports can both be used for intra-building connections. Any inter-building

connections should only be made using the fiber ports.