Messages and Alerts
SkyView Pilot’s User Guide - Revision S
12-5
Audio Alerts
When connected to an audio panel or intercom, SkyView can generate tones or voice alerts for
various conditions.
Inhibited Alerts
Audio alerts that occur within 5 seconds of SkyView initially powering on are inhibited to reduce
transient nuisance alerts that may occur as SkyView comes online.
Engine Alerts can be optionally configured to be inhibited before engine start or 5 minutes,
whichever comes first. See the SkyView System Installation Guide for details.
Messages, Alerts, and Audio Alert Details
Spoken Alert (if
configured)
Message Displayed
in Message
Window
Notification
Area Alert
(severity)
Description
“Warning”
ADAHRS FAIL
ADAHRS failure
“ADAHRS Cross Check
Error”
ADAHRS CROSS CHK
ERROR
Displayed after an ADAHRS cross-
check error was announced in a
multi-ADAHRS systems, but the
pilot did not disable one of the
disagreeing ADAHRS.
“Warning”
ADAHRS INTERNAL
ERROR
SkyView has detected a problem
with the ADAHRS module. Contact
Dynon for assistance
“Warning”
EMS FAIL
Engine monitor failure
“Engine Monitor”
“Oil Pressure”
“Fuel Pressure”
“Fuel Flow”
“Fuel Quantity”
“Electrical Current”
“Voltage”
“Exhaust Gas
Temperature”
“Cylinder Head
Temperature”
“Engine Speed”
HIGH or LOW
Engine Parameter High or Low.
“High” or “Low” is not displayed
for all parameters.
Engine Alerts can be optionally
configured to be inhibited before
engine start or 5 minutes,
whichever comes first. See the
SkyView System Installation Guide
for details.
“Warning”
ADAHRS CAL
CORRUPT
Contact Dynon for assistance