beautypg.com

Unit (ibbu) – Kontron NSN2U IP Network Server User Manual

Page 45

background image

44

5. Unscrew the protective sheet metal cover and install the hardware RAID module

using slot and screw. The opening in the top should be centered over the LSI

Logic LSISAS1078* hardware RAID controller heat sink (Figure 31, “B”).

6. Attach one end of the flex circuit cable to the connector on the SAS/SATA

hardware RAID module. Install the black plastic retention clip (included in

the accessory bag) over the flex cable connector (Figure 31, “A”). This clip

will secure the cable to the board and prevent the cable from coming loose

during shipment.

7. Line the SAS/SATA hardware RAID module bracket up close to the SAS/SATA

backplane board connector and insert the edge connector into the backplane

board.

8. Run the flex circuit cable across chassis floor (where the fan bracket was) and

connect it to the bridge board that connects the front panel board with the

T5520UR server board. See Figure 24 and Table 4 for the cable routing.

9. Replace the fan assembly bracket by inserting the guide pins into the mounting

holes on the chassis and then tightening the screw at the rear of the bracket

to secure the assembly.

10. If this is the last task you are performing inside the chassis, replace the top

front cover.

4.5 Installing a RAID Intelligent Battery Backup

Unit (IBBU)

The RAID IBBU, which is optional and separately orderable, mounts on the bottom side

of the hardware RAID module. To install the battery, you must first remove the

hardware RAID module from the chassis if it is already installed. See Section 4.4 for

the hardware RAID module procedures.

To install the battery:
1. Remove the battery cable from the kit package and attach it to the connector on the

top of the IBBU module, as shown in Figure 32.

Figure 32. Connecting the IBBU Cable

2. Turn the SAS/SATA hardware RAID module upside-down and carefully mate the IBBU

connector to the connector on the RAID module. (Figure 33, “A” and “B”)