Achronix Speedster22i PCIe User Manual
Page 52

UG030, April 26, 2013
52
Field Name
Default
Values
Description
Verilog Parameter
reported by all components
comprising the data path from
this Endpoint to the Root
Complex Root Port to determine
whether ASPM L0s entry can be
used with no loss of
performance.” Note that the
amount of buffering refers to user
application buffering. Users
should set this field in accordance
with how long a delay is
acceptable for their application.
000 - Maximum of 64 ns
001 - Maximum of 128 ns
010 - Maximum of 256 ns
011 - Maximum of 512 ns
100 - Maximum of 1 μs
101 - Maximum of 2 μs
110 - Maximum of 4 μs
111 - No limit
Non-Endpoints must
hard wire this field to
000.
L0s Exit
Latency
More
than 4us.
Less than
64ns, 64ns to
less than
128ns, 128ns
to less than
256ns, 256ns
to less than
512ns, 512ns
to less than
1us, 1us to
less than
2us, 2us-4us,
more than
4us.
L0s Exit Latency - Length of time
required to complete transition
from L0s to L0:
000 - Less than 64 ns
001 - 64 ns to less than
128 ns
010 - 128 ns to less than
256 ns
011 - 256 ns to less than
512 ns
100 - 512 ns to less than 1
μs
101 - 1 μs to less than 2 μs
110 - 2 μs-4 μs
111 - More than 4 μs
Exit latencies may be significantly
increased if the PCI Express
reference clocks used by the two
devices in the link are common or
separate.
CFG_CONTROL_PCIE_L
INK_CAP_L0S_EXIT_LA
TENCY
L1 ASPM
Support
No
No, Yes
Active State Power Management
(ASPM) Support
00 - No ASPM support
CFG_CONTROL_PCIE_L
INK_CAP_ASPM_SUPP
ORT