beautypg.com

Dell Brocade Adapters User Manual

Page 149

background image

Brocade Adapters Troubleshooting Guide

125

53-1002145-01

Adapter driver event messages

A

Authentication unsuccessful for base
port: WWN = [base port WWN or
MAC].

Error

Network and
storage driver

2 (Port)

Failure

Authentication
failure.

Mismatch of
FC-SP
configuration
between switch
and HBA. Also,
check the
authentication
secret setting.

Base port enabled: Hardware
Address = [base port WWN or MAC].

Information

Network and
storage driver

2 (Port)

Enabled

Base port enabled
by user command.

No action
required.

Base port disabled: Hardware
Address = [base port WWN or MAC].

Warning

Network and
storage driver

2 (Port)

Disabled

Base port disabled
by user command.

No action
required.

Base port online: WWN = [Base Port
WWN].

Information

Network and
storage driver

2 (Port)

Online

Base port logged
into fabric.

No action
required.

Base port offline: WWN = [Base Port
WWN].

Warning

Network and
storage driver

2 (Port)

Offline

Base port logged
out of fabric.

No action
required.

Base port (WWN = [base port WWN
or MAC]) lost fabric connectivity.

Error

Network and
storage driver

2 (Port)

Logout

Base port lost
connection with
fabric.

Check switch and
HBA
configuration.
Also, check SFP
and cable
connection
stand-up
adapters.

Heart Beat of IOC [IOC instance
number] is good.

Information

Network and
storage driver

9 (TOC)

Restart

Successful restart
of firmware after a
failure.

No action
required.

Heart Beat of IOC [IOC instance
number] has failed.

Critical

Network and
storage driver

9 (TOC)

Crash

Firmware not
responding.

Collect all error
information and
restart the
firmware. Invoke
bfa_supportsave.

IOC [IOC instance number] is
enabled.

Information

Network and
storage driver

9 (TOC)

Enabled

Adapter firmware
started by user
command.

No action
required.

IOC [IOC instance number] is
disabled.

Warning

Network and
storage driver

9 (TOC)

Disabled

Adapter firmware
stopped by user
command.

No action
required.

New adapter found: SN = [adapter
serial number] base port WWN =
[Base port WWN].

Information

Network and
storage driver

1
(Adapter)

Added

Adapter added to
host.

No action
required.

New SFP found: port [base port
number], Hardware Address = [Base
port WWN or MAC]..

Information Network

and

storage driver
(stand-up
adapters only)

2 (Port)

Found

User plugged in an
SFP.

No action
required.

QOS negotiation failed for base port:
WWN = base port WWN or MAC].

Warning

Network and
storage driver

2 (Port)

Failure

QoS negotiation
failed.

Check switch and
HBA
configuration.

TABLE 13

Driver event messages (continued)

Message

Severity

Event Type

Category

Sub
Category

Cause

Action