background image

Brocade Adapters Troubleshooting Guide

87

53-1002145-01

Statistics

3

Heartbeat failures

Firmware boots

vNIC statistics timeouts

Disable and enable requests

Disable and enable replies

Link toggle count

CEE toggle count

BPC statistics

RAD statistics

Ethernet ICO statistic timeouts

You can also select options to keep running data, set the polling frequency, start polling data, and
reset statistics.

Displaying statistics through HCM

To display statistics, perform the following steps:

1. Launch the HCM.

2. Select an FC or FCoE port from the device tree

3. Click Monitor > Statistics > vNIC Statistics.

The vNIC Statistics for Eth Port dialog box displays.

Displaying statistics through BCU

Use the vnic--stats command to display remote port statistics.

vnic --stats

where:

pcifn

PCI function number associated with the vNIC.

Virtual port statistics

Use HCM and BCU to display logical port statistics for fabric discovery (FDISC) activity, logouts
(LOGO) activity, NPIV support, number of fabrics online and offline, and fabric cleanups.

Use these statistics to isolate NPIV login problems. Following are examples of what to check if
virtual devices are not listed in the name server:

If FDISC sent and FDISC accept statistics do not match, the fabric or switch may not be ready
for data transmission. This is normal as long as it does not persist. If it does persist, there may
be a problem in the fabric or a protocol issue between the adapter and fabric. Note that in this
case FDISC retries also increase.

Check the No NPIV support statistics to verify that NPIV is supported and enabled on the
switch.