Self-monitoring analysis and reporting technology, Virtual disks and disk groups, Self-monitoring analysis and – Dell POWERVAULT MD3620I User Manual
Page 39: Reporting technology
Planning: MD3600i Series Storage Array Terms and Concepts
39
If a disk drive rebuild fails because of a source drive failure or because the
drive is too small, the MDSM reports a failure of the physical disk even
though the LED state on the drive indicates that the rebuild was aborted
(green for 3 seconds, amber for 3 seconds, then off for 3 seconds).
Self-Monitoring Analysis and Reporting Technology
SMART monitors the internal performance of all physical disk components to
detect faults indicating the potential for physical disk failure. SMART uses
this information to report whether failure is imminent so that a physical disk
can be replaced before failure occurs. The storage array monitors all attached
drives and notifies you when a predicted failure is reported by a physical disk.
Virtual Disks and Disk Groups
When configuring a storage array, you must:
1 Organize the physical disks into disk groups.
2 Create virtual disks within these disk groups.
Pending
Failure
Assigned,
Unassigned,
Hot Spare in
use, or Hot
Spare Standby
A Self-Monitoring Analysis and
Reporting Technology (SMART) error
is detected on the physical disk in the
indicated slot.
Green flashing
(500 ms), amber
(500 ms), and Off
(1000 ms)
Offline
Not applicable The physical disk has either been spun
down or had a rebuild aborted by user
request.
Green flashing
(3000 ms), amber
(3000 ms), and
Off (3000 ms)
Identify
Assigned,
Unassigned,
Hot Spare in
use, or Hot
Spare Standby
The physical disk is being identified. Green flashing
(250 ms)
N/A
N/A
The indicated slot is empty, or the
array cannot detect the physical disk.
Table 4-1. RAID Controller Physical Disk States
(continued)
Status
Mode
Description
Physical Disk
Status LED
book.book Page 39 Tuesday, June 18, 2013 3:09 PM