Configuration: About Your Storage Array

83

• Replacing an SNMP address—Select the SNMP address in the

Configured SNMP addresses area, type the replacement community

name in

Community name and the trap destination in Trap

destination, and click Replace.

• Deleting an SNMP address—Select the SNMP address in the

Configured SNMP addresses area, and click Delete.

• Validating an SNMP address—Select the SNMP address in the

Configured SNMP addresses area, and click Test. A test message is

sent to the SNMP address. A message box with the results of the

validation and any error information is displayed.

4 Click OK.

An alert icon is displayed next to each node in the Tree view for which an

alert is set.

Follow these guideline for SNMP alerts:

• Any SNMP addresses that you had previously configured are displayed in

the Configured SNMP addresses area.

• The SNMP Community Name is determined by the system administrator

and configured within the management application, such as the Dell

Management Console. More information about the Dell Management

Console is available at

dell.com.

• You can configure multiple SNMP addresses before you click

OK.

Battery Settings

A smart battery backup unit (BBU) can perform a learn cycle. The smart BBU

module includes the battery, a battery gas gauge, and a battery charger. The

learn cycle calibrates the smart battery gas gauge so that it provides a

measurement of the charge of the battery module. A learn cycle can only start

when the battery is fully charged.
The learn cycle completes the following operations:

• Discharges the battery to a predetermined threshold
• Charges the battery back to full capacity