beautypg.com

Dell POWERVAULT MD3600F User Manual

Page 62

background image

62

Planning: MD3600f Series Storage Array Terms and Concepts

• Using the Performance Monitor to retrieve performance data can affect

the normal storage array performance depending on the polling interval

that you set.

• If the storage array you are monitoring begins in or transitions to an

unresponsive state, an informational dialog is displayed. The dialog

informs you that the Performance Monitor cannot poll the storage array

for performance data.

To monitor the performance of the arrays:

1 Open MDSM and select the appropriate storage array.
2 Open the Array Management Window (AMW) for the selected

storage array.

3 In the AMW, select Storage Array Monitor Performance.
4 Click Settings.

a

Select the components that you want to monitor. You can monitor:
• RAID controller modules
• Virtual disks
• Storage array totals

NOTE:

By default, all items are selected.

b

In Polling interval, select how often you want to update the

performance statistics.

NOTE:

For an accurate elapsed time, do not use the Set RAID Controller

Module Clocks option while using the Performance Monitor.

Each time the polling interval elapses, the Performance Monitor queries

the storage array again and updates the statistics in the table.

5 Click Start.

Values are displayed for the selected storage arrays in the Performance

Monitor data table. The table is updated at the interval specified in the

Polling Interval setting.

6 Click Update to force an immediate poll of the storage array.
7 Click Stop to stop monitoring the storage array.
8 Click Save As on the Performance Monitor main dialog to save the

currently displayed performance statistics.

book.book Page 62 Tuesday, June 18, 2013 3:03 PM

This manual is related to the following products: