beautypg.com

Background initialization, Foreground initialization, Consistency check – Dell POWERVAULT MD3600F User Manual

Page 48: Media verification

background image

48

Planning: MD3600f Series Storage Array Terms and Concepts

Background Initialization

The storage array executes a background initialization when the virtual disk is

created to establish parity, while allowing full host server access to the virtual

disks. Background initialization does not run on RAID 0 virtual disks. The

background initialization rate is controlled by MDSM. To change the rate of

background initialization, you must stop any existing background

initialization. The rate change is implemented when the background

initialization restarts automatically.

Foreground Initialization

The storage array supports foreground initialization for virtual disks. All

access to the virtual disk is blocked during foreground initialization. During

foreground initialization, zeros (0x00) are written to every sector of the virtual

disk. The virtual disk is available after foreground initialization is completed.

Consistency Check

A consistency check verifies the correctness of data in a redundant array

(RAID levels 1, 5, 6, and 10). For example, in a system with parity, checking

consistency involves computing the data on one physical disk and comparing

the results to the contents of the parity physical disk.
A consistency check is similar to a background initialization. The difference is

that background initialization cannot be started or stopped manually, while

consistency check can.

NOTE:

It is recommended that you run data consistency checks on a redundant

array at least once a month. This allows detection and automatic replacement of

unreadable sectors. Finding an unreadable sector during a rebuild of a failed

physical disk is a serious problem, because the system does not have the

redundancy to recover the data.

Media Verification

Another background task performed by the storage array is media verification

of all configured physical disks in a disk group. The storage array uses the

Read operation to perform verification on the space configured in virtual

disks and the space reserved for the metadata.

book.book Page 48 Tuesday, June 18, 2013 3:03 PM

This manual is related to the following products: