beautypg.com

Monitoring md3600f series system performance – Dell POWERVAULT MD3600F User Manual

Page 61

background image

Planning: MD3600f Series Storage Array Terms and Concepts

61

• Round robin with subset—The round robin with subset I/O load balance

policy routes I/O requests, in rotation, to each available data path to the

RAID controller module that owns the virtual disks. This policy treats all

paths to the RAID controller module that owns the virtual disk equally for

I/O activity. Paths to the secondary RAID controller module are ignored

until ownership changes. The basic assumption for the round-robin policy

is that the data paths are equal. With mixed host support, the data paths

may have different bandwidths or different data transfer speeds.

• Least queue depth with subset—The least queue depth with subset policy

is also known as the least I/Os or least requests policy. This policy routes

the next I/O request to a data path that has the least outstanding I/O

requests queued. For this policy, an I/O request is simply a command in

the queue. The type of command or the number of blocks that are

associated with the command are not considered. The least queue depth

with subset policy treats large block requests and small block requests

equally. The data path selected is one of the paths in the path group of the

RAID controller module that owns the virtual disk.

• Least path weight with subset (Windows operating systems only)—The

least queue depth with subset policy is also known as the least I/Os or least

requests policy. This policy routes the next I/O request to a data path that

has the least outstanding I/O requests queued. For this policy, an I/O

request is simply a command in the queue. The type of command or the

number of blocks that are associated with the command are not

considered. The least queue depth with subset policy treats large block

requests and small block requests equally. The data path selected is one of

the paths in the path group of the RAID controller module that owns the

virtual disk.

Monitoring MD3600f Series System Performance

You can use the Performance Monitor to select virtual disks and RAID

controller modules to monitor or to change the polling interval. Keep these

guidelines in mind when using the Performance Monitor:

• The Performance Monitor does not dynamically update its display if any

configuration changes occur while the window is open. You must close the

Performance Monitor window and reopen it for the changes to be

displayed.

book.book Page 61 Tuesday, June 18, 2013 3:03 PM

This manual is related to the following products: