Installing the backplane – Dell POWERVAULT MD3600F User Manual
Page 265
Management: Installing Array Components
265
Installing the Backplane
1 Align the holes on the backplane with the holes on the array.
2 Tighten the captive screw to secure the backplane to the chassis. See
Figure 16-16 for PowerVault MD3600f or Figure 16-17 for
PowerVault MD3620f.
3 Replace the screws that secure the backplane to the chassis. See
Figure 16-16 for PowerVault MD3600f or Figure 16-17 for
PowerVault MD3620f.
4 Align the slots on the RAID controller module/power supply cage with the
tabs on the chassis. See Figure 16-15.
5 Push the RAID controller module/power supply cage toward the front of
the array.
6 Replace the screws that secure the RAID controller module/power supply
cage to the chassis.
7 Replace the control panel. See "Installing the Control Panel" on page 261.
8 Replace the power supply/cooling fan modules. See "Installing a Power
Supply/Cooling Fan Module" on page 258.
9 Replace the hard drives. See "Installing a Hard Drive" on page 246.
10 Connect all the cables to the array.
11 Turn on the array and the host server.
book.book Page 265 Tuesday, June 18, 2013 3:03 PM