beautypg.com

Dell PowerEdge R415 User Manual

Page 52

background image

52

About Your System

Warning: Front
Control Panel is
not installed.

The control panel is not

installed or has a faulty cable

connection.

Install the control panel, or

check the cable connections

between the control panel

board and the system board.

See "Troubleshooting

System Memory" on

page 157.

Write fault.
Write fault on
selected drive.

Faulty USB device, USB

medium, optical drive

assembly, hard-drive, or hard-

drive subsystem.

Replace the USB medium or

device. Ensure that the USB,

SAS backplane, or SATA

cables are properly

connected. See

"Troubleshooting a USB

Device" on page 150,

"Troubleshooting an

Internal USB Key" on

page 159, and

"Troubleshooting a Hard

Drive" on page 163.

Incorrect memory
configuration
CPU n.

The DIMM group for CPU n

is incorrectly configured and

caused the system to halt.

See "General Memory

Module Installation

Guidelines" on page 122, for

memory configuration

information. If the problem

persists, see

"Troubleshooting System

Memory" on page 157.

HyperTransport
error caused a
system reset!
Please check the
system event log
for details!

A fatal system error occurred

and caused the system to

reboot.

Check the SEL for

information that is logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" on page 149,

for any faulty components

specified in the SEL.

Table 1-3. System Messages

(continued)

Message

Causes

Corrective Actions

R415HOM.book Page 52 Friday, September 24, 2010 9:37 AM