Dell PowerEdge R415 User Manual
Page 52

52
About Your System
Warning: Front
Control Panel is
not installed.
The control panel is not
installed or has a faulty cable
connection.
Install the control panel, or
check the cable connections
between the control panel
board and the system board.
Write fault.
Write fault on
selected drive.
Faulty USB device, USB
medium, optical drive
assembly, hard-drive, or hard-
drive subsystem.
Replace the USB medium or
device. Ensure that the USB,
SAS backplane, or SATA
cables are properly
connected. See
Incorrect memory
configuration
CPU n.
The DIMM group for CPU n
is incorrectly configured and
caused the system to halt.
memory configuration
information. If the problem
persists, see
HyperTransport
error caused a
system reset!
Please check the
system event log
for details!
A fatal system error occurred
and caused the system to
reboot.
Check the SEL for
information that is logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
for any faulty components
specified in the SEL.
Table 1-3. System Messages
(continued)
Message
Causes
Corrective Actions
R415HOM.book Page 52 Friday, September 24, 2010 9:37 AM