Dell PowerEdge R415 User Manual
Page 33

About Your System
33
E1810 Hard drive ##
fault. Review
& clear SEL.
The specified hard-drive
has experienced a fault.
E1812 Hard drive ##
removed. Check
drive.
The specified hard-
drive has been removed
from the system.
Information only.
E1920 iDRAC6 Upgrade
Failed
The iDRAC6 Express card
is not installed properly or
the card is bad.
Reseat the iDRAC6
Express Card. See
Installing an iDRAC6
Express Card. If the
problem persists, see
E1A11 PCI Riser
hardware &
configuration
mismatch.
Reconfigure.
PCIe risers are not
configured correctly.
Some invalid
configurations prevent the
system from powering on.
Reinstall the expansion-
card riser. See "Expansion
Card Riser" on page 99.
If the problem persists,
the riser card or system
board is faulty. See
E1A12 PCI Riser not
detected.
Check Riser.
One or both of the PCIe
risers are missing. This
prevents the system from
powering on.
Reinstall the missing
riser. See "Expansion
E1A14 SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
Table 1-2. LCD Status Messages (Optional)
(continued)
Code
Text
Causes
Corrective Actions
R415HOM.book Page 33 Friday, September 24, 2010 9:37 AM