beautypg.com

Dell PowerEdge R415 User Manual

Page 34

background image

34

About Your System

E1A15 SAS cable B

failure. Check
connection.

SAS cable B is missing

or bad.

Reseat the cable. If the

problem persists,

replace cable.
If the problem persists,

see "Getting Help" on

page 181.

E1A1D Control panel

USB cable not
detected.
Check cable.

USB cable to the control

panel is missing or bad.

Reseat the cable. If the

problem persists, replace

cable.
If the problem persists,

see "Getting Help" on

page 181.

E2010 Memory not

detected.
Inspect DIMMs.

No memory was detected

in the system.

Install memory or reseat

memory modules. See

"Installing Memory

Modules" on page 124 or

"Troubleshooting System

Memory" on page 157.

E2011 Memory

configuration
failure.
Check DIMMs.

Memory detected, but is

not configurable.

Error detected during

memory configuration.

See "Troubleshooting

System Memory" on

page 157.

E2012 Memory

configured but
unusable.
Check DIMMs.

Memory configured, but is

unusable.

See "Troubleshooting

System Memory" on

page 157.

E2013 BIOS unable to

shadow memory.
Check DIMMs.

The system BIOS failed to

copy its flash image into

memory.

See "Troubleshooting

System Memory" on

page 157.

E2014 CMOS RAM

failure. Power
cycle AC.

CMOS failure. CMOS

RAM not functioning

properly.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 181.

Table 1-2. LCD Status Messages (Optional)

(continued)

Code

Text

Causes

Corrective Actions

R415HOM.book Page 34 Friday, September 24, 2010 9:37 AM