Dell PowerEdge R415 User Manual
Page 27

About Your System
27
E1410 System Fatal
Error
detected.
A fatal system error
detected.
Check LCD for
additional scrolling
messages. Remove AC
power to the system for
10 seconds and restart the
system. If the problem
persists, see "Getting
E1414 CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out
of acceptable temperature
range.
Ensure that the processor
heat sinks are properly
installed. See
E1418 CPU # not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Ensure that the specified
microprocessor is
properly installed. See
E141C Unsupported
CPU
configuration.
Check CPU or
BIOS revision.
Processors are in an
unsupported
configuration.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
E141F CPU # protocol
error. Power
cycle AC.
The system BIOS
has reported a processor
protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
Table 1-2. LCD Status Messages (Optional)
(continued)
Code
Text
Causes
Corrective Actions
R415HOM.book Page 27 Friday, September 24, 2010 9:37 AM