About Your System

E1710 I/O channel

check error.
Review & clear
SEL.

The system BIOS has

reported an I/O channel

check.

Check the SEL for more

information and then

clear the SEL. Remove

AC power to the system

for 10 seconds and restart

the system.
If the problem persists,

see "Getting Help" on

page 181.

E1711 PCI parity

error on Bus
## Device ##
Function ##

The system BIOS has

reported a PCI parity

error on a component

that resides in PCI

configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 165.

PCI parity
error on Slot
#. Review &
clear SEL.

The system BIOS has

reported a PCI parity

error on a component

that resides in the

specified slot.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 165.

Table 1-2. LCD Status Messages (Optional)

(continued)

Code

Text

Causes

Corrective Actions

R415HOM.book Page 30 Friday, September 24, 2010 9:37 AM