Table C-2. LTO Tape Drive Sense Data (continued)

Byte

Bit Address or Name

7

6

5

4

3

2

1

0

12-13

Additional Sense Code (ASC) -
Additional Sense Code Qualifier (ASCQ) (Continued)
Byte 12 Byte 13
ASC ASCQ
27

00 - Write Protect - A Write type operation has been requested on a cartridge which

has been write protected

28

00 - Not Ready to Ready Transition - A cartridge has been loaded successfully into

the drive and is now ready to be accessed

28

01 - Import or export element accessed

29

00 - Reset - The drive has powered on, received a reset signal or a bus device

reset signal since the initiator last accessed it

29

04 - Device internal reset

2A

01 - Mode Parameters Changed - The Mode parameters for the drive have

been changed by an initiator other than the one issuing the command

2C

00 - Command sequence error

2C

0B - Not reserved - The OIR bit of the sequential access device page

is set and the I-T nexus attempting to communicate with the drive does not hold
a reservation.

2F

00 - Commands cleared by another initiator

30

00 - Incompatible Media Installed - A write type operation could not be

executed because it is not supported on the cartridge type that is loaded.

30

01 - Unknown Format - An operation could not be carried out because the cartridge

in the drive is of a format not supported by the drive

30

02 - Incompatible Format - An operation could not be completed because the

Logical Format is not correct

30

03 - Cleaning Cartridge Installed - An operation could not be carried out

because the cartridge in the drive is a cleaning cartridge

30

05 - Cannot write medium, incompatible format

30

07 - Cleaning Failure - A cleaning operation was attempted, but could not

be completed for some reason

30

0C - Data Protect - WORM overwrite attempted. The drive rejected a write operation

because it would have resulted in an overwrite. Overwrite is not allowed on
WORM media.

30

0D - Medium Error - WORM integrity check. The drive rejected a Read or Write

operation because the cartridge is a suspicious WORM cartridge.

31

00 - Media format corrupted - Data could not be read because the format on tape is

not valid, but is a known format. A failure occurred attempting to write the FID

37

00 - Rounded parameter - A Mode Select command parameter has been

rounded because the drive can not store it with the accuracy of the command.

3A

00 - Media Not Present - A media access command has been received

when there is no cartridge loaded

3B

00 - Sequential Positioning Error - A command has failed and left the logical

position at an unexpected location

3B

0C - Position past beginning of medium

3D

00 - Invalid bits in identify Message - An illegal Identify Message has been

received at the drive at the start of a command

3E

00 - Logical Unit has not Self-Configured - The drive has just powered on and

has not completed its self test sequence and can not process commands

3F

01 - Code Download - The firmware in the drive has just been changed

by a Write Buffer command

3F

03 - Inquiry data has changed

3F

0E - Reported LUNs data has changed

3F

0F - Echo buffer overwritten

40

xx - Diagnostic failure - A diagnostic test has failed. The xx (ASCQ) is a

vendor specific code indicating the failing component.