Table 8-2. Sub error codes (continued)
97
Slot not free at robot unload
98
Cartridge not seated in load phase
Warning events
Warning events that are described are reported by way of email notification. The
Attention LED flashes when warning events for the following occur:
v
Media
v
Fan
v
Redundant power supply
An appropriate message is posted on the Operator Control Panel and the Web
User Interface.
Table 8-3. Warning events
30
SCSI: transport element full
Refer to your host application documentation for problem
determination information.
31
SCSI: all slots empty
32
SCSI: invalid opcode
33
SCSI: invalid element address
34
SCSI: invalid field in CDB
35
SCSI: Invalid drive specified
36
SCSI: SEND DIAGNOSTIC command:
invalid test number
37
SCSI: invalid LUN
38
SCSI: parameter list length error
39
SCSI: parameter list error: invalid field
3A
SCSI: parameter list error: parameter not
supported
3B
SCSI: parameter value invalid
3C
SCSI: saving parameters not supported
3D
SCSI: invalid ID message
3E
SCSI: destination element full
3F
SCSI: source slot or drive empty
40
SCSI: wrong checksum
41
SCSI: command sequence error
42
SCSI: drive disabled
Check your configuration settings.
43
SCSI: I/O Station disabled
44
SCSI: flash image does not fit bootcode
Refer to your host application documentation for problem
determination information.
45
SCSI: media removal prevented by drive
46
SCSI: media removal prevented by
library
47
SCSI: flash image does not fit personality Check the version of firmware that is used for the upgrade.
Chapter 8. Error codes