Table 8-2. Sub error codes (continued)

97

Slot not free at robot unload

98

Cartridge not seated in load phase

Warning events

Warning events that are described are reported by way of email notification. The
Attention LED flashes when warning events for the following occur:

v

Media

v

Fan

v

Redundant power supply

An appropriate message is posted on the Operator Control Panel and the Web
User Interface.

Table 8-3. Warning events

30

SCSI: transport element full

Refer to your host application documentation for problem
determination information.

31

SCSI: all slots empty

32

SCSI: invalid opcode

33

SCSI: invalid element address

34

SCSI: invalid field in CDB

35

SCSI: Invalid drive specified

36

SCSI: SEND DIAGNOSTIC command:
invalid test number

37

SCSI: invalid LUN

38

SCSI: parameter list length error

39

SCSI: parameter list error: invalid field

3A

SCSI: parameter list error: parameter not
supported

3B

SCSI: parameter value invalid

3C

SCSI: saving parameters not supported

3D

SCSI: invalid ID message

3E

SCSI: destination element full

3F

SCSI: source slot or drive empty

40

SCSI: wrong checksum

41

SCSI: command sequence error

42

SCSI: drive disabled

Check your configuration settings.

43

SCSI: I/O Station disabled

44

SCSI: flash image does not fit bootcode

Refer to your host application documentation for problem
determination information.

45

SCSI: media removal prevented by drive

46

SCSI: media removal prevented by
library

47

SCSI: flash image does not fit personality Check the version of firmware that is used for the upgrade.