Configure: Set Date and Time
Use this menu item to set the current date and time in your library.
Configure: Path Failover
Use this menu item to enter the Path Failover Feature Activation key (Supported
on 4U library only for library firmware levels at or below 8.xx. Supported on both
the 2U and 4U libraries with library firmware levels above 8.xx).
Library firmware levels higher than 8.xx support Path Failover on LTO 5 and LTO
4 drives. For LTO Ultrium 6 Tape Drives use Library firmware B.50 or greater if
you want to support Path Failover. For more information, refer to the Dell
PowerVault TL2000/TL4000 Failover Configuration Guide, included with the library
documentation.
Service Menu
The 2U/4U library is always online, except for when the user enters the Service
Library area. A warning message appears stating that the library should be taken
offline from the host before performing any Service functions. It is up to the
operator to ensure that it is taken offline by phoning the host operator or other
means of communication. Before performing any service functions, ensure the host
is not performing any data writing or retrieval.
The Service Menu contains the following items:
v
Library Verify - an overall library diagnostic
v
Run Tests - other library diagnostics
v
Service - diagnostics and procedures for servicing the drive
v
Display Contrast - setting the display from light to dark
v
Telnet Service Port
Service: Library Verify
This is an overall diagnostic that exercises all library components. To run the
Library Verify test, complete the following procedure.
Configure
Set Date
and Time
a77ug046
Figure 5-20. Configure: Set Date and Time menu
Configure
Path Failover
a77ug
11
9
Figure 5-21. Configure: Path Failover
Chapter 5. Operations