beautypg.com

Compaq Professional Workstation AP200 User Manual

Page 144

background image

E-4 Error Codes

Writer: M. Church Project: Compaq Professional Workstation AP200 Reference Guide Comments: 352620-003

File Name: L-APPE.DOC Last Saved On: 12/14/98 2:40 PM

COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

Power-On Self Test Message

Continued

Message

Beeps*

Probable Cause

Recommended Action

201-Memory Error

None

RAM failure

1.

Make sure your
memory module(s)
(if any) are installed
properly.

2. Replace

the

memory module(s).

3.

Replace the system
board.

203-Memory Address

Error

None

RAM failure

1.

Make sure your
memory module(s)

2. Replace

the

memory module(s).

3.

Replace the system
board.

207-ECC Corrected

Single Bit Errors in

DIMM/SIMM Pair(s) X,

X, ...

2S

Single Bit ECC error

Replace DIMM if error

persists.

213-Incompatible

DIMM Module in

DIMM Socket(s) X, X,

...

2S

A DIMM module in DIMM

socket identified in the error

message is missing critical

SPD information, or it is

incompatible with the chipset.

Replace the DIMM with a

module conforming to

the SPD standard. See

Chapter 4, “Hardware

Upgrades.”

* L = Long, S = Short

Continued