Overview, Cascadeable ez-screen, 4 determining interconnect cordset lengths – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual
Page 60: Ez-screen lp instruction manual

58
P/N 133487
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Overview
58
P/N 140044 rev.
E
Banner Engineering Corp.
•
Minneapolis, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
EZ-SCREEN LP
Instruction Manual
Cascadeable EZ-SCREEN
7.4 Determining Interconnect Cordset Lengths
The following Cordset length charts are possible combinations
for each side of example cascaded systems. Model DELP-..E
cordsets (24 awg wire) used for calculations. Other lengths and
combinations are possible; please call factory for assistance.
As the machine interface Cordset lengthens, the voltage drop
Machine Interface Cordset (L1)
QDE-8..D or RDLP-8..D
0.9 m (3')
4.6 m (15')
7.6 m (25')
15.2 m (50')
Example Cordset pairing per side of cascaded system
Sensor
Interconnect
Cordset Lengths
(L2)
Max. L2*
58.2 m (191')
47.5 m (156') 38.4 m (126')
16.2 m (53')
Individual
DELP-1
1..E
Cordsets
30.5 m (100')
30.5 m (100’)
30.5 m (100')
22.9 m (75')
22.9 m (75')
22.9 m (75')
15.2 m (50')
15.2 m (50')
15.2 m (50')
15.2 m (50')
7.6 m (25')
7.6 m (25')
7.6 m (25')
7.6 m (25')
4.6 m (15')
4.6 m (15')
4.6 m (15')
4.6 m (15')
2.4 m (8')
2.4 m (8')
2.4 m (8')
2.4 m (8')
0.9 m (3')
0.9 m (3')
0.9 m (3')
0.9 m (3')
0.3 m (1')
0.3 m (1')
0.3 m (1')
0.3 m (1')
0.1 m (0.33')
0.1 m (0.33')
0.1 m (0.33')
0.1 m (0.33')
Example 1:
Example 2:
Machine Interface Cordset (L1): 4.6 m (15')
Machine Interface Cordset (L1): 15.2 m (50')
Sensor Interconnect Cordset (L2): 45.7 m (150'), using one 30.5 m (100') and
Sensor Interconnect Cordset (L2): 15.2 m (50') or shorter
one 15.2 m (50') DELP..-.. cordset, or 30.5 m (100') or shorter using single cordsets
Figure 7-2. Cordset length options for two cascaded light screens
Figure 7-3. Cordset length options for three cascaded light screens
increases, which results in shorter possible interconnect Cordsets
to maintain supply voltage requirements at the cascaded sensor.
See Section 2 for Cordsets.Due to the large number of possible
combinations, the table in Figure 7-4 includes only applications
in which L2 = L4. A common installation example is one that
protects two areas of a machine (e.g., the front and back of a
power press) and uses four EZ-SCREEN LP pairs to create two
“L”-shaped sensing fields.
Example 1:
Example 2:
Machine Interface Cordset (L1): 0.9 m (3')
Machine Interface Cordset (L1): 4.6 m (15')
Sensor Interconnect Cordset (L2): 22.9 m (75')
Sensor Interconnect Cordset (L2): 7.6 m (25')
Sensor Interconnect Cordset (L3): 7.6 m (25') or shorter
Sensor Interconnect Cordset (L3): 22.9 m (75') or shorter
*Multiple DELP..-.. cordsets may be required.
*Multiple DELP..-.. cordsets may be required.
Machine Interface Cordset
(L1) QDE-8..D or RDLP-8..D
0.9 m (3')
4.6 m (15')
7.6 m (25')
15.2 m (50')
Example Cordset pairing per side of cascaded system
Sensor
Interconnect
Cordset
Lengths (L2, L3)
L2
L3
L2
L3
L2
L3
L2
L3
Max. L2*
28.7 m
(94')
0.3 m
(1')
22.3 m
(73')
0.3 m
(1')
16.8 m
(55')
0.3 m
(1')
3 m
(10')
0.3 m
(1')
Max. L3*
0.3 m
(1')
57.0 m
(187')
0.3 m
(1')
43.9 m
(144')
0.3 m
(1')
32.9 m
(108')
0.3 m
(1')
5.8 m
(19')
Individual
DELP-1
1..E
Cordsets
22.9 m (75')
7.6 m (25')
15.2 m (50') 22.9 m (75') 15.2 m (50') 15.2 m (50') 15.2 m (50')
2.4 m (8')
7.6 m (25') 30.5 m (100') 7.6 m (25') 22.9 m (75') 7.6 m (25') 15.2 m (50')
4.6 m (15') 30.5 m (100') 4.6 m (15') 30.5 m (100') 4.6 m (15') 22.9 m (75')
2.4 m (8')
30.5 m (100')
2.4 m (8')
30.5 m (100')
2.4 m (8')
22.9 m (75')
2.4 m (8')
0.9 m (3')
0.9 m (3')
30.5 m (100')
0.9 m (3')
30.5 m (100')
0.9 m (3')
30.5 m (100') 0.9 m (3')
4.6 m (15')
0.3 m (1')
30.5 m (100')
0.3 m (1')
30.5 m (100')
0.3 m (1')
30.5 m (100') 0.3 m (1')
4.6 m (15')
0.1 m (0.33') 30.5 m (100') 0.1 m (0.33') 30.5 m (100') 0.1 m (0.33') 30.5 m (100') 0.1 m (0.33') 4.6 m (15')
L2
L1
EZ-SCREEN
LP Position
#2
Emitters
Machine
Control
Receivers
L3
EZ-SCREEN
LP Position
#1
EZ-SCREEN
LP Position
#3
L2
L1
EZ-SCREEN
LP Position
#2
Emitters
Machine
Control
Receivers
EZ-SCREEN
LP Position
#1