beautypg.com

Overview, Installation and alignment, 1 safety distance (minimum distance) – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 23: 1 mechanical installation considerations, Warning

background image

P/N 133487

21

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

P/N 140044 rev.

E

21

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP
Instruction Manual

Installation and Alignment

3.1.1 Safety Distance (Minimum Distance)

Separation or Safety Distance (Ds), also called Minimum

Distance (S), is the minimum distance required between the

defined area and the closest reachable hazard point. The

distance is calculated so that when an object or a person is

detected (by blocking a sensing beam), the EZ-SCREEN LP will

send a stop signal to the machine, causing it to stop before the

person can reach any machine hazard point.
The distance is calculated differently for domestic U.S. and

European installations. Both methods take into account several

factors, including a calculated human speed, the total system

stopping time (which itself has several components), and the

depth penetration factor. After the distance is determined,

record the calculated distance on the Daily Checkout Card.

3. Installation and Alignment

3.1 Mechanical Installation Considerations

The two factors that most influence the layout of the

EZ-SCREEN LP’s mechanical installation are safety (minimum)

distance and hard guarding. Other considerations include emitter

and receiver orientation, adjacent reflective surfaces, use of

corner mirrors, and installation of multiple EZ-SCREEN LP

emitter/receiver pairs.

Before installing the EZ-SCREEN LP, read Section 1.2 and

Section 3 of this manual in their entirety. The System’s

ability to perform its safety guarding function depends upon

the appropriateness of the application and upon its proper

mechanical and electrical installation and interfacing to the

guarded machine. If all mounting, installation, interfacing, and

checkout procedures are not followed properly, the System

cannot provide the protection for which it was designed.

Installation must be performed by a Qualified Person, as defined

in Section 4.1. See Warning below.

Figure 3-1. Safety (minimum) distance and hard guarding

WARNING . . .

Position Components

Carefully

The emitter and receiver must be positioned such that the
hazard can not be accessed by reaching over, under, around
or through the sensing field.
Additional guarding may be required;
see Separation Distance, Section 3.1.1, and Pass-Through Hazards,
Section 3.1.2, and Supplemental Safeguarding, Section 3.1.4.

WARNING . . .

Minimum Safety Distance

EZ-SCREEN LP emitters and receivers must be mounted at a
distance from the nearest hazard such that an individual cannot
reach the hazard before cessation of hazardous motion or situation.
Failure to establish and maintain the minimum distance could
result in serious bodily injury or death.

Reduced Resolution
Reduced Resolution increases Dpf (or C). Increase the depth
penetration factor to calculate proper minimum distance
whenever Reduced Resolution is used.
Always turn Reduced
Resolution OFF when the larger minimum object detection size is
not required.

WARNING . . .

Read this Section Carefully

Before Installing the System

The user is responsible for satisfying all local, state, and
national codes and regulations relating to the installation and
use of this control system in any particular application.
Take
extreme care to meet all legal requirements and follow all technical
installation and maintenance instructions contained in this manual.
The user has the sole responsibility to ensure that the
EZ-SCREEN LP System is installed and interfaced to the
guarded machine by Qualified Persons in accordance with this
manual and with applicable safety regulations.
Read Section 1.2 and all of Section 3 of this manual carefully before
installing the System. Failure to follow these instructions could
result in serious bodily injury or death.

Hard Guarding (Fixed Guarding)

Turn-

table

EZ-SCREEN LP

Reset Switch

Ds

Nearest Hazard Point

Robot

Hard Guarding

(Fixed Guarding)

EZ-SCREEN LP