beautypg.com

Overview, System operation, 1 security protocol – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 44: 2 system configuration settings

background image

42

P/N 133487

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

42

P/N 140044 rev.

E

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP

Instruction Manual

System Operation

4. System Operation

4.1 Security Protocol

Certain procedures for installing, maintaining and operating

the EZ-SCREEN LP must be performed by either Designated

Persons or Qualified Persons.
A Designated Person is identified and designated in writing,

by the employer, as being appropriately trained and qualified to

perform system resets and the specified checkout procedures

on the EZ-SCREEN LP System. The Designated Person is

empowered to:

• Perform manual resets and hold possession of the reset key

(see Section 4.3), and

• Perform the daily checkout procedure (see Section 6).
A Qualified Person, by possession of a recognized degree or

certificate of professional training, or by extensive knowledge,

training and experience, has successfully demonstrated the

ability to solve problems relating to the installation of the

EZ-SCREEN LP and its integration with the guarded machine.

In addition to everything for which the Designated Person is

empowered, the Qualified Person is empowered to:

• Install the EZ-SCREEN LP,

• Perform all checkout procedures (see Section 6),

• Make changes to the internal configuration settings, and

• Reset the System following a Lockout condition.

4.2 System Configuration Settings

If not previously configured, System settings are made on the

configuration panels located on each sensor, behind the access

door. The access door is opened by loosening the factory-

installed screw. See Figure 4-1.
The receiver has redundant Trip/Latch and Reduced Resolution

DIP switches, which must be set identically (see Section 4.2).

Failure to do so will cause a Lockout condition when power is

applied. If the corresponding pairs of DIP switches are not

set identically, the EZ-SCREEN LP will not operate.
Power to the EZ-SCREEN LP receiver should be OFF when

changing DIP switch settings (other than Scan Code) or a

Lockout will occur.
After configuration settings are verified/set, fully close the

access door and tighten the screw to maintain the sensor IP

rating.

Figure 4-1. Accessing the configuration switches

Table 4-1. DIP Switch Settings

Underlined entries indicate factory defaults. “Left” and “right” refer to
positions as shown in Figure 4-1.

Label

Left Position (

)

Right Position (

→)

T/L

Trip Output

Latch Output

RED RES

2-Beam Reduced
Resolution enabled

Reduced Resolution OFF

SCAN

Scan Code 2

Scan Code 1

EDM

1-Channel EDM (E1)

2-Channel EDM (E2)

AUX/FLT

Aux (OSSD follow)

Fault (lockout)

INVERT

Inverted display

OFF (Standard display)

TEST
(Emitter)

Test function

Reset function

FAULT
(Emitter)

ON

OFF

Loosen M2 (Phillips #1) screw,
then rotate hinged door to access
DIP switches

Receiver