beautypg.com

Overview, System operation, 6 periodic checkout requirements – Banner EZ-SCREEN Low-Profile Safety Light Curtain Systems User Manual

Page 49: 5 normal operation, Warning

background image

P/N 1334

47

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Overview

P/N 140044 re

v. E

47

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN LP
Instruction Manual

System Operation

During Run Mode

Trip Output Configuration: If any beams become blocked

while the EZ-SCREEN LP is running with trip output selected,

the receiver outputs turn OFF within the stated EZ-SCREEN

LP response time (see Specifications). If all the beams then

become clear, the receiver outputs come back ON. No resets

of any kind are needed. All required machine control resets are

provided by the machine control circuit.
Latch Output Configuration: If any beams become blocked

while the EZ-SCREEN LP is running with latch output selected,

the receiver outputs turn OFF within the stated EZ-SCREEN

LP response time (see Specifications). If all the beams then

become clear, the receiver Zone indicators will all be Green and

the Reset indicator single-flashes, indicating the EZ-SCREEN

LP is waiting for a manual latch reset. In latch output operation,

the outputs come back ON only when all beams are clear and

after a manual reset. The EZ-SCREEN LP will wait for a manual

reset; when a valid reset signal is received and all beams

remain clear, the receiver outputs turn ON.
Internal Faults (Lockouts): If either sensor detects a critical

fault, scanning ceases, the receiver outputs turn OFF and

diagnostic information is displayed on the sensor’s 7-segment

display. See Section 5 for resolution of error/fault conditions.

4.6 Periodic Checkout Requirements

To ensure continued reliable operation, the System must be

checked out periodically.
At every shift change, power-up and machine setup

change, the Daily checkout should be performed; this checkout

may be performed by a Designated or Qualified Person (see

Section 6.3 and the Daily Checkout Card for the procedure).
Semi-annually, the EZ-SCREEN LP and its interface to the

guarded machine should be thoroughly checked out; this

checkout must be performed by a Qualified Person (see Section

6.4). A copy of these test results should be posted on or near

the machine.
Whenever changes are made to the System (either a

new configuration of the EZ-SCREEN LP or changes to the

machine), the Commissioning Checkout should be performed

(see Section 6.2).

4.5 Normal Operation

System Power-Up

The EZ-SCREEN LP will power up in one of two ways,

depending on the trip/latch output configuration. If it is set for

trip output, it will power up and reset automatically; if it is set

for latch output, it will require a manual reset procedure after

power-up and sensor alignment.
Trip Output Power-Up: When power is applied, each sensor

conducts self-tests to detect critical internal faults, determine

configuration settings, and prepare the EZ-SCREEN LP for

operation. (If either sensor detects a critical fault, scanning

ceases, the receiver outputs remain OFF and diagnostic

information is displayed on the sensor’s 7-segment display.)

If no faults are detected, the EZ-SCREEN LP automatically

enters Alignment mode, and the receiver looks for an optical

sync pattern from the emitter. If the receiver is aligned and

receives the proper sync pattern, it enters Run mode and begins

scanning to determine the blocked or clear status of each beam.

No manual reset operation is required.
Latch Output Power-Up: When power is applied, each sensor

conducts self-tests to detect critical internal faults, determine

configuration settings, and prepare for operation. (If either

sensor detects a critical fault, scanning ceases, the receiver

outputs remain OFF and diagnostic information is displayed on

the sensor’s 7-segment display.) If no faults are detected, the

EZ-SCREEN LP automatically enters Alignment mode, and the

receiver looks for an optical sync pattern from the emitter. If

the receiver is aligned and receives the proper sync pattern, it

begins scanning to determine the blocked or clear status of each

beam. When all beams are aligned, the Yellow Reset indicator

double-flashes to indicate the EZ-SCREEN LP is waiting for a

manual reset. After a valid manual reset, the EZ-SCREEN LP

enters Run mode and continues scanning.

WARNING . . .

Verify Proper Operation

It is the user’s responsibility to verify proper operation, on a regular
basis, as instructed in Section 6. Failure to correct such problems
can result in serious bodily injury or death.